Project name |
Parameter |
Specification |
LCD screen |
size |
10.4 inch |
Touch screen |
size |
10.4 inch |
Power Adapter |
Standard operating voltage range |
100ï½240Vac, typical 220Vac |
Input voltage range |
90ï½264Vac, typical 220Vac |
|
Body temperature |
Display precise digits |
0.1 â |
Human body temperature measurement mode |
32.0ï½42.5â |
|
Object temperature measurement mode |
0ï½100â |
|
Accuracy |
â¤Â±0.3â |
|
Power consumption |
â¤120mw |
|
Measuring distance |
5 to 8 cm |
|
Automatic shut-down |
About 15 seconds |
|
Blood sugar, Uric acid, Total cholesterol |
Specimen |
Fingertip Microvascular Whole Blood |
Detection time |
Blood sugar: within 10 seconds Uric acid: within 15 seconds Total cholesterol: within 26 seconds |
|
examination range |
Glucose: 20-600mg/dL (1.1-33.3mmol/L) Uric acid: 3-20mg/dL (0.18-1.19mmol/L) Total cholesterol: 100-400mg/dL (2.59-10.35mmol/L) |
|
Sample volume |
Blood sugar 0.9uL, total cholesterol 10uL, uric acid 1uL |
|
Storage temperature |
10â-30â |
|
Operating temperature |
10â-40â |
|
Relative humidity |
ï¼95% |
|
Memory capacity |
Blood sugar 360 group, total cholesterol 50 group, uric acid 50 group |
|
Battery type |
A 3V (CR2032) button type lithium battery |
|
Battery Life |
Approximately 1000 times |
|
Blood Pressure Monitor |
Display method |
Large-screen LCD digital |
Measurement methods |
Oscillometric method |
|
Measuring range |
Blood pressure: 30ï½280mmHg |
|
Pulse rate: 40ï½195 beats/min |
||
Accuracy |
Pressure ±3mmHg |
|
Pulse rate ±5% |
||
Pressurize/Relieve |
Use microelectronic air pump control system to pressurize/relieve pressure |
|
Storage function |
100 sets of measurement values, including date/time (without losing memory) |
|
Suitable for arm circumference |
22cmï½32cm |
|
power supply |
DC 6V |
|
Use temperature and humidity |
+5â-+40â RHâ¤80% (measured outside the range, the measurement result has deviation) |
|
Storage temperature and humidity |
-20â-+55â RHâ¤93% (measured outside the range, the measurement result has deviation) |
|
Operating atmospheric pressure |
525-795mmHg |
|
Atmospheric pressure for transportation and storage |
375-795mmHg |
|
Single-lead ECG |
Operating temperature |
5âï½40â |
Ambient temperature |
30%ï½80% non-condensing |
|
Atmospheric pressure range |
70KPaï½106KPa |
|
Heart rate measurement range |
30bpmï½240bpm |
|
Heart rate measurement accuracy |
±2bpm or ±2%, whichever is the maximum |
|
Waveform display sensitivity |
5.0mm/mv error ±10% |
|
Scan speed |
20mm/s error ±10% |
|
input resistance |
â¥5.0Ω |
|
Operating Voltage |
d.c.3V±0.2V |
|
Blood oxygen |
sensor |
Dual wavelength light emitting diode |
wavelength |
Red light: 663nm |
|
Infrared light: 890nm |
||
Measuring range |
35%ï½100%; |
|
Maximum average optical output power |
â¤2mW |
|
Measurement error |
In the range of 70%ï½100%, the measurement error is ±2% |
|
Pulse rate measurement error |
30ï½250bpm The monitoring error is ±2bpm or ±%2, whichever is the largest |
|
Data output interface |
LAN network interface |
|
voltage |
220 AC (50Hz/60Hz) |
|
rated power |
(100W) maximum |
|
Operating humidity range (storage temperature range) |
5âï½45â(-10âï½+60â) |
|
ID card recognizer |
Second generation ID card recognizer |
|
operating system |
Windows 7 32-bit or higher |