Health check machine: | SK-T8X | ||
Level | Class I, type B | ||
Height | Height sensor | Ultrasound probe(Buy from USA) | |
Range | 70.0~200cm | ||
Accuracy | 0.01cm | ||
Weight | BMI | Automatic calculation | |
Loadcell | 500kg | ||
Accuracy | ±0.1kg | ||
Body composition analysis | Frequencies | 5kHz/50kHz/250kHz/500kHz | |
Measurement | Body fat, visceral fat, body water, muscle, bone mass, basal metabolism | ||
Measurement current | 90μA or below | ||
Electrode material | Electroplating material | ||
Measurement range | 75.0~1,500.00Ω(0.1Ω unit) | ||
Measurement location | Trunk, 4 limbs | ||
Body temperature | Test method | Infrared wireless hand-held temperature gun | |
Accurate to | 0.1 ℃ | ||
Operation & storage temperature | 10~40℃, 0~50℃ | ||
Operation & storage humidity | ≤85% | ||
Power | DC 9V | ||
Dimension | 150*75*40mm | ||
Weight | 180g | ||
Human temperature range | 32.0~42.5℃ | ||
Object temperature range | 0~100℃ | ||
Accuracy | ≤±0.3℃ | ||
Power consumption | ≤120mw | ||
Detection distance | 5 to 8 cm | ||
Auto-off | after 15 seconds | ||
Blood pressure monitor | Blood pressure range | (0~270)mmHg,[(0~36)Kpa] Pulse rate: 40-180bpm | |
Storage capacity | 100 pcs of record | ||
Accuracy | Blood pressure: <±2mmHg(±0.267kpa) | ||
Pulse: <±2% | |||
Power | AC 100-240V,50-60Hz,1.6-0.8A | ||
Operation temperature & humidity | 5℃~40℃ 15%RH~80%RH | ||
Transport & storage temperure & humidity | -20℃~55℃ <93%RH | ||
Operation atmospheric pressure | 80Kpa~106Kpa | ||
Transport & storage atmospheric pressure | 50Kpa~106Kpa | ||
Dimension | 471.5mm(L)*402.0mm(W)*309.0mm(H) | ||
Electric shock protection | Class I, type B | ||
Device weight | 8kg | ||
Arm circumference | 17-42cm | ||
Blood oxygen | Probe | Dual-wavelength LED | |
Wave length | Red light: 663nm, Infrared: 890nm | ||
Range | 35%~100% | ||
Power of maximum light output | ≤2mW | ||
Blood oxygen rate accuracy | Range: 70%~100%, ±2% | ||
Pulse rate accuracy | Range: 30~250bpm, ±2% | ||
Operation temperature | 5℃~40℃ | ||
Operation humidity | 15%~95% | ||
Atmospheric pressure | 70kpa~106kpa | ||
Power input | From main device by RS232 | ||
ECG | Leads | 6 or 12 leads | |
Collection | Syhchronization | ||
Calibration voltage | 1mV±5% | ||
Polarization resistance voltage | ±300mV | ||
Sensitivity | 5, 10, 20(mm/mV) | ||
Input impedance | ≥5MΩ | ||
Input loop current | <0.05uA | ||
Heart rate range | 20-300bmp/min | ||
Noise level | ≤15uVp-p | ||
Filtering | EMG Filtering | ||
Baseline filtering | |||
AC filtering | |||
Common mode rejection ratio | >90dB | ||
Time constant | ≥3.2s | ||
Frequency response | 0.05Hz~150Hz(-3.0dB/+0.4dB) | ||
Rhythmic lead | Any leads optional | ||
Base line adjustment | Automatic | ||
Patient leak current | <10uA(220V-240V) | ||
Patient auxiliary current | ≤0.1uA(DC) | ||
Safety standard | IEC II/CF | ||
Sampling frequency | 500Hz | ||
Electrode | Chest electrodes and limb electrodes adopt international colors, each matches different color | ||
Blood glucose Uric acid Total cholesterol | Measurement range | Blood glucie: 1.1-33.3mmol/L(20-600mg/dL) Uric acid: 0.18-1.19mmol/L(3-20mg/dL) cholesterol: 2.59-10.35mmol/L(100-400mg/dL) | |
Measurement time | blood glucoe: 5s±0.5s Uric acid: 15S±0.5S Total cholesterol: 26S±0.5S | ||
Reference for normal | Blood glucose before meal: 3.9mmol/L-6.1 mmol/L Blood glucose after 2 hours of meal: <7.8 mmol/L | ||
Uric acid of male: 0.21~0.43mmol/L | |||
Uric acid of female: 0.16~0.36mmol/ | |||
Uric acid of children: 0.12~0.33mmol/L | |||
Total cholesterol: 2.86~5.98mmol/L | |||
Accuracy | ±0.3(test by standard resistance slip) | ||
Display | mmol/Lx and time display | ||
Inbuilt battery | 3V Lithium battery | ||
Lipid profile | Sample type | Capillary vessel whole blood sample, venous blood | |
Type | Total cholesterol | ||
HDL: High density Lipoprotein | |||
TG: Triglyceride | |||
LDL: Low density Lipoprotein(By calculation) | |||
Method | Enzymatic colorimetric analysis | ||
Mesurement range | Total cholesterol: 100-400mg/dL(2.6-10.3mmol/L) | ||
Triglyceride: 70-600mg/dL(0.8-6.8mmol/L) | |||
High density Lipoprotein: 25-80mg/dL(0.8-2.1mmol/L) | |||
Test period | About 120 seconds | ||
Calibration | Plasma or similar product | ||
Sample volumn | 5 microlitre | ||
Blood glucose | Sample type | Capillary vessel whole blood sample | |
Mesurement range | 10-600 mg/dL(0.6-33.3mmol/L) | ||
Sample volumn | 0.3 microlitre | ||
Test period | 3 seconds | ||
Calibration | Plasma or similar product | ||
HCT range | 20-60% | ||
RFID | Standard: IS0/IEC 15693 | ||
Read/write distance: 2cm | |||
Antenna: integrated | |||
Frequence: 13.56MHz | |||
Measurement theory for blood glucose | Electrochemistry, Optical spectrum | ||
Storage capacity | 200 | ||
Operation temperature | Lipid profile: 18-30℃(64-86℉) Blood glucose: 10-40℃ (50-104℉) | ||
Operation humidity | 10-90% | ||
Storage temperature | 2-30℃(36-80℉) | ||
Display | LCD | ||
Dimension | 61*109*23(mm) | ||
Weight | 77.5(with battery)±1g | ||
Battery life time | >1000 cycle use | ||
Advertisement screen | Display screen | 19" LCD screen, visible under sunshine | |
Opertion screen | Display screen | 17" LCD screen | |
Dimension | Package dimension: | 121(L)*190(H)*140(W)cm | |
Machine dimension: | 242(H)*174(L)*61(W)cm | ||
Inbuilt PC and processor | Gifa® industrial board, Intel 4 core CPU | ||
Operation system | Windows 7 32bits OS | ||
A4 printer | HP-P1106 | ||
Data output port | TCP/IP | ||
Voltage | 220 AC (50Hz/60Hz) | ||
Power consumption | 100W(Max.) | ||
Operation and storage temperature | 5℃~45℃(-10℃~+60℃) | ||
Machine weight | 76kg |