Telemedicine Kiosk:
|
SK-T9
|
|
Height
|
Height sensor
|
Ultrasound probe(Buy from USA)
|
Range
|
70.0~200cm
|
|
Accuracy
|
0.01cm
|
|
Weight
|
BMI
|
Automatic calculation
|
Loadcell
|
500kg
|
|
Accuracy
|
±0.1kg
|
|
Body composition analysis
|
Frequencies
|
5kHz/50kHz/250kHz/500kHz
|
Measurement
|
Body fat, visceral fat, body water, muscle, bone mass, basal metabolism
|
|
Measurement current
|
90μA or below
|
|
Electrode material
|
Electroplating material
|
|
Measurement range
|
75.0~1,500.00Ω(0.1Ω unit)
|
|
Measurement location
|
Trunk, 4 limbs
|
|
Body temperature
|
Test method
|
Infrared wireless hand-held temperature gun
|
Accurate to
|
0.1 ℃
|
|
Operation & storage temperature
|
10~40℃, 0~50℃
|
|
Operation & storage humidity
|
≤85%
|
|
Power
|
DC 9V
|
|
Dimension
|
150*75*40mm
|
|
Weight
|
180g
|
|
Human temperature range
|
32.0~42.5℃
|
|
Object temperature range
|
0~100℃
|
|
Accuracy
|
≤±0.3℃
|
|
Power consumption
|
≤120mw
|
|
Detection distance
|
5 to 8 cm
|
|
Auto-off
|
after 15 seconds
|
|
Blood pressure monitor
|
Blood pressure range
|
(0~270)mmHg,[(0~36)Kpa]
Pulse rate: 40-180bpm |
Storage capacity
|
100 pcs of record
|
|
Accuracy
|
Blood pressure: <±2mmHg(±0.267kpa)
|
|
Pulse: <±2%
|
||
Power
|
AC 100-240V,50-60Hz,1.6-0.8A
|
|
Operation temperature & humidity
|
5℃~40℃ 15%RH~80%RH
|
|
Transport & storage temperure & humidity
|
-20℃~55℃ <93%RH
|
|
Operation atmospheric pressure
|
80Kpa~106Kpa
|
|
Transport & storage atmospheric pressure
|
50Kpa~106Kpa
|
|
Dimension
|
471.5mm(L)*402.0mm(W)*309.0mm(H)
|
|
Electric shock protection
|
Class I, type B
|
|
Device weight
|
8kg
|
|
Arm circumference
|
17-42cm
|
|
Blood oxygen
|
Probe
|
Dual-wavelength LED
|
Wave length
|
Red light: 663nm, Infrared: 890nm
|
|
Range
|
35%~100%
|
|
Power of maximum light output
|
≤2mW
|
|
Blood oxygen rate accuracy
|
Range: 70%~100%, ±2%
|
|
Pulse rate accuracy
|
Range: 30~250bpm, ±2%
|
|
Operation temperature
|
5℃~40℃
|
|
Operation humidity
|
15%~95%
|
|
Atmospheric pressure
|
70kpa~106kpa
|
|
Power input
|
From main device by RS232
|
|
ECG
|
Leads
|
6 or 12 leads
|
Collection
|
Syhchronization
|
|
Calibration voltage
|
1mV±5%
|
|
Polarization resistance voltage
|
±300mV
|
|
Sensitivity
|
5, 10, 20(mm/mV)
|
|
Input impedance
|
≥5MΩ
|
|
Input loop current
|
<0.05uA
|
|
Heart rate range
|
20-300bmp/min
|
|
Noise level
|
≤15uVp-p
|
|
Filtering
|
EMG Filtering
|
|
Baseline filtering
|
||
AC filtering
|
||
Common mode rejection ratio
|
>90dB
|
|
Time constant
|
≥3.2s
|
|
Frequency response
|
0.05Hz~150Hz(-3.0dB/+0.4dB)
|
|
Rhythmic lead
|
Any leads optional
|
|
Base line adjustment
|
Automatic
|
|
Patient leak current
|
<10uA(220V-240V)
|
|
Patient auxiliary current
|
≤0.1uA(DC)
|
|
Safety standard
|
IEC II/CF
|
|
Sampling frequency
|
500Hz
|
|
Electrode
|
Chest electrodes and limb electrodes adopt international colors, each matches different color
|
|
Blood glucose
Uric acid Total cholesterol |
Measurement range
|
Blood glucose: 1.1-33.3mmol/L(20-600mg/dL)
Uric acid: 0.18-1.19mmol/L(3-20mg/dL) cholesterol: 2.59-10.35mmol/L(100-400mg/dL) |
Measurement time
|
blood glucose: 5s±0.5s
Uric acid: 15S±0.5S Total cholesterol: 26S±0.5S |
|
Reference for normal
|
Blood glucose before meal: 3.9mmol/L-6.1 mmol/L
Blood glucose after 2 hours of meal: <7.8 mmol/L |
|
Uric acid of male: 0.21~0.43mmol/L
|
||
Uric acid of female: 0.16~0.36mmol/
|
||
Uric acid of children: 0.12~0.33mmol/L
|
||
Total cholesterol: 2.86~5.98mmol/L
|
||
Accuracy
|
±0.3(test by standard resistance slip)
|
|
Display
|
mmol/Lx and time display
|
|
Inbuilt battery
|
3V Lithium battery
|
|
Blood glucose
|
Sample type
|
Capillary vessel whole blood sample
|
Mesurement range
|
10-600 mg/dL(0.6-33.3mmol/L)
|
|
Sample volume
|
0.3 microlitre
|
|
Test period
|
3 seconds
|
|
Calibration
|
Plasma or similar product
|
|
HCT range
|
20-60%
|
|
RFID
|
Standard: IS0/IEC 15693
|
|
Read/write distance: 2cm
|
||
Antenna: integrated
|
||
Frequence: 13.56MHz
|
||
Measurement theory for blood glucose
|
Electrochemistry, Optical spectrum
|
|
Storage capacity
|
200
|
|
Operation temperature
|
Lipid profile: 18-30℃(64-86℉)
Blood glucose: 10-40℃ (50-104℉) |
|
Operation humidity
|
10-90%
|
|
Storage temperature
|
2-30℃(36-80℉)
|
|
Display
|
LCD
|
|
Dimension
|
61*109*23(mm)
|
|
Weight
|
77.5(with battery)±1g
|
|
Battery life time
|
>1000 cycle use
|
Copyright © - Privacy policy