Model No. |
SK-T8X |
||
Level |
Class I, type B |
||
Height |
Height sensor |
Ultrasound probe(Buy from USA) |
|
Accuracy |
0.01cm |
||
Weight |
BMI |
Automatic calculation |
|
Loadcell |
500kg |
||
Accuracy |
±0.1kg |
||
Body composition analysis |
Frequencies |
5kHz/50kHz/250kHz/500kHz |
|
Measurement |
Body fat, visceral fat, body water, muscle, bone mass, basal metabolism |
||
Measurement current |
90μA or below |
||
Electrode material |
Electroplating material |
||
Measurement range |
75.0~1,500.00Ω(0.1Ω unit) |
||
Measurement location |
Trunk, 4 limbs |
||
Body temperature |
Test Method |
Infrared wireless hand-held temperature gun |
|
Accurate to |
0.1 ℃ |
||
Operation & storage temperature |
10~40℃, 0~50℃ |
||
Operation & storage humidity |
≤85% |
||
Power |
DC 9V |
||
Dimension |
150*75*40mm |
||
Weight |
180g |
||
Human temperature range |
32.0~42.5℃ |
||
Object temperature range |
0~100℃ |
||
Accuracy |
≤±0.3℃ |
||
Power consumption |
≤120mw |
||
Detection distance |
5 to 8 cm |
||
Auto-off |
after 15 seconds |
||
Blood pressure monitor |
Blood pressure range |
"(0~270)mmHg,[(0~36)Kpa] Pulse rate: 40-180bpm" |
|
Storage capacity |
100 pcs of record |
||
Accuracy |
Blood pressure: <±2mmHg(±0.267kpa)Pulse: <±2% |
||
Power |
AC 100-240V,50-60Hz,1.6-0.8A |
||
Operation temperature & humidity |
5℃~40℃ 15%RH~80%RH |
||
Transport & storage temperure & humidity |
-20℃~55℃ <93%RH |
||
Operation atmospheric pressure |
80Kpa~106Kpa |
||
Transport & storage atmospheric pressure |
50Kpa~106Kpa |
||
Dimension |
471.5mm(L)*402.0mm(W)*309.0mm(H) |
||
Electric shock protection |
Class I, type B |
||
Device weight |
8kg |
||
Arm circumference |
17-42cm |
||
Blood oxygen |
Probe |
Dual-wavelength LED |
|
Wave length |
Red light: 663nm, Infrared: 890nm |
||
Range |
35%~100% |
||
Power of maximum light output |
≤2mW |
||
Blood oxygen rate accuracy |
Range: 70%~100%, ±2% |
||
Pulse rate accuracy |
Range: 30~250bpm, ±2% |
||
Operation temperature |
5℃~40℃ |
||
Operation humidity |
15%~95% |
||
Atmospheric pressure |
70kpa~106kpa |
||
Power input |
From main device by RS232 |
||
ECG |
Leads |
6 or 12 leads |
|
Collection |
Syhchronization |
||
Calibration voltage |
1mV±5% |
||
Polarization resistance voltage |
±300mV |
||
Sensitivity |
5, 10, 20(mm/mV) |
||
Input impedance |
≥5MΩ |
||
Input loop current |
<0.05uA |
||
Heart rate range |
20-300bmp/min |
||
Noise level |
≤15uVp-p |
||
Filtering |
EMG Filtering |
||
Baseline filtering |
|||
AC filtering |
|||
Common mode rejection ratio |
>90dB |
||
Time constant |
≥3.2s |
||
Frequency response |
0.05Hz~150Hz(-3.0dB/+0.4dB) |
||
Rhythmic lead |
Any leads optional |
||
Base line adjustment |
Automatic |
||
Patient leak current |
<10uA(220V-240V) |
||
Patient auxiliary current |
≤0.1uA(DC) |
||
Safety standard |
IEC II/CF |
||
Sampling frequency |
500Hz |
||
Electrode |
Chest electrodes and limb electrodes adopt international colors, each matches different color |
||
"Blood glucose Uric acid Total cholesterol" |
Measurement range |
Blood glucie: 1.1-33.3mmol/L(20-600mg/dL) Uric acid: 0.18-1.19mmol/L(3-20mg/dL) cholesterol: 2.59-10.35mmol/L(100-400mg/dL) |
|
Measurement time |
blood glucoe: 5s±0.5s Uric acid: 15S±0.5S Total cholesterol: 26S±0.5S |
||
Reference for normal |
Blood glucose before meal: 3.9mmol/L-6.1 mmol/L Blood glucose after 2 hours of meal: <7.8 mmol/L |
||
Uric acid of male: 0.21~0.43mmol/L |
|||
Uric acid of female: 0.16~0.36mmol/ |
|||
Uric acid of children: 0.12~0.33mmol/L |
|||
Total cholesterol: 2.86~5.98mmol/L |
|||
Accuracy |
±0.3(test by standard resistance slip) |
||
Display |
mmol/Lx and time display |
||
Inbuilt battery |
3V Lithium battery |
||
Lipid profile |
Sample type |
Capillary vessel whole blood sample, venous blood |
|
Type |
Total cholesterol |
||
HDL: High density Lipoprotein |
|||
TG: Triglyceride |
|||
LDL: Low density Lipoprotein(By calculation) |
|||
Method |
Enzymatic colorimetric analysis |
||
Mesurement range |
Total cholesterol: 100-400mg/dL(2.6-10.3mmol/L) |
||
Triglyceride: 70-600mg/dL(0.8-6.8mmol/L) |
|||
High density Lipoprotein: 25-80mg/dL(0.8-2.1mmol/L) |
|||
Test period |
About 120 seconds |
||
Calibration |
Plasma or similar product |
||
Sample volume |
5 microlitre |
||
Blood glucose |
Sample type |
Capillary vessel whole blood sample |
|
Measurement range |
10-600 mg/dL(0.6-33.3mmol/L) |
||
Sample volume |
0.3 microlitre |
||
Test period |
3 seconds |
||
Calibration |
Plasma or similar product |
||
HCT range |
20-60% |
||
RFID |
Standard: IS0/IEC 15693 |
||
Read/write distance: 2cm |
|||
Antenna: integrated |
|||
Frequence: 13.56MHz |
|||
Measurement theory for blood glucose |
Electrochemistry, Optical spectrum |
||
Storage capacity |
200 |
||
Operation temperature |
"Lipid profile: 18-30℃(64-86℉) Blood glucose: 10-40℃ (50-104℉)" |
||
Operation humidity |
10-90% |
||
Storage temperature |
2-30℃(36-80℉) |
||
Display |
LCD |
||
Dimension |
61*109*23(mm) |
||
Weight |
77.5(with battery)±1g |
||
Battery life time |
>1000 cycle use |
||
Advertisement screen |
Display screen |
19" LCD screen, visible under sunshine |
|
Opertion screen |
Display screen |
17" LCD screen |
|
Dimension |
Package dimension: |
121(L)*190(H)*140(W)cm |
|
Machine dimension: |
242(H)*174(L)*61(W)cm |
||
Inbuilt PC and processor |
Gifa® industrial board, Intel 4 core CPU |
||
Operation system |
Windows 7 32bits OS |
||
A4 printer |
HP-P1106 |
||
Data output port |
TCP/IP |
||
Voltage |
220 AC (50Hz/60Hz) |
||
Power consumption |
100W (Max.) |
||
Operation and storage temperature |
5℃~45℃(-10℃~+60℃) |
||
Machine weight |
76kg |