Machine parameters |
Data output interface |
LAN network port*1 USB*2 |
Power supply |
100V~240V,50/60Hz |
|
Power rating |
(100W)Maximum |
|
LCD screen |
21.5inch |
|
ID card reader |
||
Operating humidity range (storage temperature range) |
5℃~45℃(-10℃~+60℃) |
|
Operating System |
Windows 10 (More than 32) |
|
Data Transmission Mode |
internet access、WIFI |
|
Overall Dimension |
1800(length)*1200( Width)*2450(height )mm |
|
Weight |
About 220KG |
|
Height |
Measuring system |
Ultrasonic measurement (high precision temperature difference compensation) |
Measuring range |
70.0~205cm |
|
Permissible error |
±0.5cm |
|
Weight |
Measuring system |
Precision balance beam pressure sensor weighing |
BMI |
The automatic intelligence calculates the body mass index |
|
Measuring range |
1~300kg |
|
Permissible error |
±0.1kg |
|
Body fat |
Measuring frequency |
Multi frequency 4- electrode |
Electrode material |
Electroplating material |
|
Measuring range |
200~1000Ω |
|
Body temperature (DT-8836) |
Display exact number |
0.1 ℃ |
Human body temperature measurement |
32.0~42.5℃ |
|
Object temperature measurement |
0~100℃ |
|
Accuracy |
≤±0.3℃ |
|
Power Consumption |
≤120mw |
|
Measuring distance |
5-8cm |
|
Auto Power -Off |
About 15 second |
|
Blood pressure(RBP-7000) |
Display |
Digital display |
Measuring method |
Oscillographic method |
|
Measuring range |
Pressure (0~300) mmHg [ (0~ 40)kPa] rate 30/minute~200/minute |
|
Accuracy |
Pressure 士2mmHg(士0.267kPa)within Rate士2% within |
|
Screen |
LCD screen |
|
Data Transmission Mode |
232 port/USB |
|
Power Supply |
Power Adapter(Input AC100V~240V,50/60Hz,Output DC12V,3.5A) |
|
Operating temperature and humidity |
5℃~40℃,15%RH~80%RH |
|
Transport and storage temperature and humidity |
-20℃~+55℃,≤93%RH |
|
Operating atmospheric pressure |
80kPa~106kPa |
|
Transport and storage atmospheric pressure |
50kPa~106kPa |
|
Overall dimensions |
387.7mm(L)×244.1mm(W)×340.2mm(H) |
|
Net Weight |
About 6.0Kg |
|
Cuff applies to perimeter range |
17cm~42cm |
|
Blood oxygen KS-CM01 |
Sensor |
Dual wavelength light emitting diode |
Wavelength |
Red Lights:663nm |
|
Infrared light:890nm |
||
Measuring range |
35%~100%; |
|
Maximum average optical Output power |
≤2mW |
|
Permissible error |
The measurement error was ±2% in the range of 70% to 100% |
|
Pulse rate measurement error |
Tolerance of 30-250bpm was ±2bpm or ±%2, which was the maximum |
|
Single lead ECG |
Operating temperature |
5℃~40℃ |
Environment temperature |
30%~80% Non - Condensing |
|
Range of atmospheric Pressure |
70KPa~106KPa |
|
Heart rate measurement range |
30bpm~240bpm |
|
Accuracy of heart rate Measurement |
The maximum value is ± 2BPM or ±2 |
|
Waveform display sensitivity |
5.0mm/mv error±10% |
|
Scanning speed |
20mm/s error±10% |
|
Input impedance |
≥5.0Ω |
|
Operating voltage |
d.c.2.5V±0.2V |
|
Blood sugar, uric acid, total cholesterol (BeneCheck BKM13-1) |
Specimens |
Whole fingertip micro-vascular blood |
Detection time |
Blood sugar 10 seconds; uric acid 15 seconds; total cholesterol 26 seconds |
|
Measuring range |
blood glucose:20-600mg/dL (1.1-33.3mmol/L) Uric Acid:3-20mg/dL(0.18-1.19mmol/L) Total cholesterol:100-400mg/dL(2.59-10.35mmol/L) |
|
Liquid volume inspector |
blood glucose 0.9uL,Total cholestero l10uL, Uric Acid 1uL |
|
Storage Temperature |
10℃-30℃ |
|
Operating Temperature |
10℃-40℃ |
|
Relative humidity |
<95% |
|
Memory capacity |
Blood glucose 360 group, total cholesterol 50 group, uric acid 50 group |
|
Battery type |
A 3V (CR2032) button lithium battery |
|
Validity of battery |
About 1000 tests |
|
Camera |
Pixels |
5 million |
Port |
USB 2.0 |
|
Driver |
free drive |
|
Thermal printer(SP-EU58) |
Printing method |
Line thermal printing |
Printing paper |
(straight roll) Heat sensitive 57.5mm× paper roll 100mm (MAX) |
|
Carriage Paper Width |
57.5±0.5 mm |
|
Effective print width |
48mm |
|
Image resolution |
8 /mm(203dp) |
|
Printing speed |
Max 80mm/S(No more than 25% print points per line) |
|
Paper thickness |
0.06~0.08 mm |
|
Print head span |
50KM |
|
Operating ambient temperature/humidity |
0-50℃/10-80% |
|
Temperature/humidity of the storage environment |
-20-60℃/10-90% |