Project Name |
Parameter |
Specification |
Complete machine parameters |
Data output interface |
LAN network interface * 1, USB * 1, DB9 * 1 |
operating system |
Android |
|
Operating humidity range (storage temperature range) |
5℃~45℃(-10℃~+60℃) |
|
ID card reader |
Second generation ID card identifier&ID card |
|
Voltage range/frequency range |
100~240V AC / (50Hz/60Hz) |
|
QR code scanning instrument |
QR code |
|
Body temperature detection |
Inductive measurement |
|
10.1 inch display screen |
21.5 inch touch screen resolution 1920 * 1080 |
|
Data transmission mode |
Internet port, WIFI, RS232 communication, Bluetooth |
|
Overall power |
≤50W |
|
Overall dimensions |
1060 (L) * 1069 (W) * 2365 (H) mm |
|
weight |
About 80KG |
|
height |
measurement system |
Ultrasonic measurement (high-precision temperature difference compensation) |
measuring range |
90.0~205cm |
|
Allowable error |
±0.5cm |
|
weight |
measurement system |
Weighing by precision balance beam pressure sensor |
body mass index |
Automatically and intelligently calculate body mass index |
|
measuring range |
1~300kg |
|
Allowable error |
±0.1kg |
|
Blood pressure meter (pulse wave 7000 type) |
Display method |
Digital display method |
measuring method |
Oscillometry |
|
measuring range |
Pressure (0~300) mmHg [(0~40) kPa] Pulse rate 30 times/min~200 times/min“ The pressure is within ± 2mmHg (± 0.267kPa) |
|
accuracy |
Pulse rate less than 2%“ |
|
screen |
LCD screen |
|
transmission mode |
232 serial port/USB |
|
Power Supply |
Power adapter (input a.c.100V~240V, 50/60Hz, output d.c.12V, 3.5A) |
|
Operating temperature and humidity |
5℃~40℃,15%RH~80%RH |
|
Transportation and storage temperature and humidity |
-20℃~+55℃,≤93%RH |
|
Operating atmospheric pressure |
80kPa~106kPa |
|
Atmospheric pressure for transportation and storage |
50kPa~106kPa |
|
Overall dimensions |
387.7mm long × 244.1mm wide × 340.2mm high |
|
Main engine weight |
About 6.0Kg |
|
Applicable circumference of cuff |
17cm~42cm |
|
Blood oxygen (KREK KS-CM01) |
sensor |
Dual wavelength LED |
wavelength |
Red light: 663nm |
|
Infrared light: 890nm |
||
measuring range |
35%~ 100%; |
|
Maximum average optical output power |
≤2mW |
|
measurement error |
Within the range of 70%~100%, the measurement error is ± 2% |
|
Pulse rate measurement error |
30~250bpm monitoring error is ± 2bpm or ±% 2, whichever is the maximum |
|
Micro printer(Sprite SP - RME3SHB) |
Printing method |
Row thermal sensitivity |
Print paper width |
58mm |
|
Print Width |
48mm |
|
resolving power |
8 points/mm (203dpi) |
|
Printing speed |
Max 100mm/S (no more than 25% print points per line) |
|
Power requirements |
DC9~24V,2A |
|
Body temperature (Kellipo DT-8836) |
Display exact digits |
0.1 ℃ |
Human body temperature measurement mode |
32.0~42.5℃ |
|
Object temperature measurement mode |
0~100℃ |
|
accuracy |
≤±0.2℃(35℃~42.0℃) |
|
power waste |
≤120mw |
|
Measuring distance |
5 to 8 cm |
|
Automatic shutdown |
About 15 seconds |
Copyright © - Privacy policy