Project Name |
Parameter |
Specification |
|
Model |
SK-T6 |
||
Machine parameters
|
Data output interface |
LAN network interface * 1 USB * 2 |
|
supply voltage |
100V~240V, 50/60Hz |
||
Rated power |
(100W) Maximum |
||
LCD screen |
15 inches 1024 * 768 |
||
Advertising screen |
21.5 inches 1920 * 1080 |
||
ID card recognizer |
Second-generation ID card recognizer |
||
Working humidity range (storage temperature range) |
5 ℃~45 ℃ (-10 ℃~+60 ℃) |
||
operating system |
Windows 7 32-bit and above |
||
Data transmission method |
Network interface WIFI |
||
Overall dimensions |
1599 (length) * 877.5 (width) * 2430.9 (height) mm |
||
weight |
Approximately 100KG |
||
measurement system |
Ultrasonic measurement (high-precision temperature difference compensation) |
||
measuring range |
70.0-200cm |
||
Allowable error |
± 0.5cm |
||
measurement system |
Precision balance beam pressure sensor weighing |
||
body mass index |
Automatically and intelligently calculating body mass index |
||
measuring range |
1-300kg |
||
Allowable error |
± 0.1kg |
||
Measurement frequency band |
Multi frequency 4-electrode |
||
Electrode material |
Electroplating materials |
||
measuring range |
200-1000 Ω |
||
Display exact digits |
0.1 ℃ |
||
Human body temperature measurement mode |
32.0~42.5 ℃ |
||
accuracy |
≤ ± 0.3 ℃ |
||
power dissipation |
≤ 120kw |
||
Measure distance |
5 to 8 centimeters |
||
Automatic shutdown |
About 15 seconds |
||
Collection method |
12 lead synchronous electrocardiogram |
||
Power input |
d. C5.0V (powered by computer USB port)/dc3.0V (powered by alkaline battery) |
||
sampling frequency |
500Hz |
||
Calibration voltage |
Calibration voltage: 1 mV+5%. |
||
Gain setting and accuracy |
5 mm/mV (x0.5), 10 mm/mV (x1), and 20 mm/mV (x2) should be provided |
||
Input impedance |
≥ 5.0 Ω |
||
Low frequency characteristics |
Time constant not less than 3.2 seconds |
||
Paper feeding speed |
At least three levels of 12.5 mm/s, 25 mm/s, and 50 mm/s, with an error range of ± 5% |
||
Operating temperature |
5 ℃~40 ℃ |
||
ambient temperature |
30% to 80% non condensing |
||
Atmospheric pressure range |
70KPa~106KPa |
||
Heart rate measurement range |
30bpm~240bpm |
||
Heart rate measurement accuracy |
Take the maximum value of ± 2bpm or ± 2% |
||
Waveform display sensitivity |
5.0mm/mv error ± 10% |
||
scanning speed |
20mm/s error ± 10% |
||
Input impedance |
≥ 5.0 Ω |
||
working voltage |
d. C. 2.5V ± 0.2V |
||
measuring range |
Pressure (0-300) mmHg [(0-40) kPa] |
||
Measurement accuracy |
Pulse rate: 30 times/minute~200 times/minute,Pressure within 2mm Hg (± 0.267 kPa),Pulse rate within 2% |
||
screen |
LCD screen |
||
transmission mode |
232 serial port/USB |
||
Power supply |
Power adapter (input a.c. 100V~240V, 50/60Hz, output d. c. 12V, 3.5A) |
||
Using temperature and humidity |
5 ℃~40 ℃, 15% RH~80% RH |
||
Transportation and storage temperature and humidity |
-20 ℃~+55 ℃, ≤ 93% RH |
||
Operating atmospheric pressure |
80kPa~106kPa |
||
Transportation and storage atmospheric pressure |
50kPa~106kPa |
||
External dimensions |
387.7mm (length) x 244.1mm (width) x 340.2mm (height) |
||
Host weight |
Approximately 6.0Kg |
||
Cuff straps are suitable for circumference range |
17cm~42cm |
||
sensor |
Dual wavelength light-emitting diode |
||
wavelength |
Red light: 663nm;Infrared light: 890nm |
||
measuring range |
35% to 100% |
||
Maximum average optical output power |
≤ 2mW |
||
measurement error |
Within the range of 70% to 100%, the measurement error is ± 2% |
||
Pulse rate measurement error |
The monitoring error between 30-250bpm is ± 2bpm or ±% 2, whichever is the maximum |
||
Physical examination |
Fingertip microvascular whole blood |
||
Detection time |
Blood glucose: 10 seconds Uric acid: 15 seconds Total cholesterol: 26 seconds |
||
Detection scope |
Blood glucose: 20-600mg/dL (1.1-33.3mmol/L) Uric acid: 3-20mg/dL (0.18-1.19mmol/L) Total cholesterol: 100-400mg/dL (2.59-10.35mmol/L) |
||
Examination volume |
Blood glucose 0.9uL, total cholesterol 10uL, uric acid 1uL |
||
Storage temperature |
10 ℃ -30 ℃ |
||
Operating temperature |
10 ℃ -40 ℃ |
||
relative humidity |
<95% |
||
Memory capacity |
Blood glucose 360 group, total cholesterol 50 group, uric acid 50 group |
||
Battery type |
A 3V (CR2032) button type lithium battery |
||
Battery life |
Can be measured approximately 1000 times |
||
resolving power |
Black and white (best mode): up to 1200x1200dpi; Black and white (normal mode): up to 600x600dpi |
||
Printer Language |
GDI (Host Language Based) |
||
Printing speed |
Black and white (normal mode, A4): Up to 20 pages/minute; Black and white (long edge feed), A5): Up to 30 pages/minute |
||
Print load |
Up to 10000 pages |
||
First printing time |
Black and white (A4, ready mode): only 8.3 seconds; Black and white (A4, sleep mode): up to 18 seconds |
||
weight |
4.18 kg |
||
interface |
High speed USB 2.0 port |
||
system parameter |
Windows?: 7 (32/64 bit), 2008 Server R2,8 (32/64 bit), 8.1 (32/64 bit), 10 (32/64 bit), 2012 Server, 2016 Server |
||
size |
331 * 215 * 178 millimeters |
||
Memory |
64 MB |
||
source |
Power type: built-in power supply; Power requirements: 110V input voltage: 110-127V AC, 50/60Hz; 220V input voltage: 220-240V AC, 50/60Hz |