The Sonka Portable 3-in-1 Blood Glucose, Cholesterol, and Uric Acid Testing Device is a multifunctional medical follow-up package designed for comprehensive health monitoring. This advanced portable ECG blood glucose meter integrates a 2-in-1 blood pressure and blood glucose monitor, providing a complete solution for home healthcare, telemedicine, and mobile medical services. With high-precision testing capabilities, it enables users to monitor key health indicators accurately and conveniently. Its compact, lightweight design makes it an ideal tool for both personal and professional healthcare use.
Product Type
|
SK-GS6
|
||
Project name
|
Parameter
|
Specification
|
|
Body Temperature
|
Display precise digits
|
0.1 â
|
|
Human body temperature measurement mode
|
32.0ï½42.5â
|
||
Object temperature measurement mode
|
0ï½100â
|
||
Accuracy
|
â¤Â±0.3â
|
||
Measuring distance
|
5 to 8 cm
|
||
Automatic shut-down
|
About 15 seconds
|
||
Blood Pressure
|
Measuring range
|
Pressure (0ï½270)mmHg [(0ï½36)kpa]
|
|
Pulse rate 40 times/per minuteï½180 times/minute
|
|||
Measurement accuracy
|
Pressure within ±3mmHg (±0.4kpa)
|
||
Pulse rate within ±5%
|
|||
Applicable circumference range of cuff
|
15cmï½42cm
|
||
12-lead ECG
|
Collection method
|
12-lead synchronous ECG Wilson
|
|
Sampling frequency
|
500Hz
|
||
Gain setting and accuracy
|
Should provide 5 mm/mV (x0.5), 10 mm/mV (x1), 20 mm/mV (x2)
|
||
Blood Oxygen
|
Measuring range
|
35%~ 100%;
|
|
Maximum average optical output power
|
â¤2mW
|
||
Measurement error
|
In the range of 70%ï½100%, the measurement error is ±2%
|
||
Pulse rate measurement error
|
30ï½250bpm The monitoring error is ±2bpm or ±%2, whichever is the largest
|
||
Blood Sugar, Uric Acid, Total Cholesterol
|
Specimen
|
Fingertip microvascular whole blood
|
|
Detection time
|
Blood sugar: within 10 seconds Uric acid: within 15 seconds Total cholesterol: within 26 seconds
|
||
examination range
|
Blood sugar: 20-600mg/dL (1.1-33.3mmol/L)
Uric acid: 3-20mg/dL (0.18-1.19mmol/L) Total cholesterol: 100-400mg/dL (2.59-10.35mmol/L) |
||
Urinalysis
|
Detection principle
|
RGB three primary color detection principle
|
|
interface
|
Micro USB interface, Bluetooth wireless communication (Bluetooth version machine)
|
||
Relative humidity
|
â¤80%
|
||
Dimensions
|
126mm(L)*74mm(W)*30mm(H)
|
||
Hemoglobin
|
measure time
|
â¤10 seconds
|
|
Equipment detection range
|
7.0-26.0g/dL (4.3-161.1mmol/L); 20-75% blood cell volume (converted)
|
||
Power Adapter
|
Standard operating voltage range
|
100ï½240Vac, typical 220Vac
|
|
Motherboard
|
CPU
|
Super quad-core Cortex-A17, frequency up to 1.8GHz
|
|
GPU
|
ARM Mali-T764 GPU, support TE, ASTC, AFBC memory compression technology
|
Copyright © 2025 by Shenzhen Sonka Medical Technology Co., Limited - Privacy policy