Touchscreens |
size |
15.6 |
(body) temperature |
Displaying the exact number of digits |
0.1 °C |
Body temperature measurement mode |
32.0 to 42.5°C |
|
Object temperature measurement mode |
0 to 100°C |
|
precision |
≤±0.3°C |
|
power wastage |
≤120mw |
|
measuring distance |
5 to 8 cm |
|
automatic shutdown |
About 15 seconds. |
|
12-lead ECG |
Collection method |
12-lead synchronized ECG Wilson |
Power input |
d.c5.0V (powered by computer USB port) |
|
Sampling frequency |
500Hz |
|
Calibration voltage |
Calibration voltage:1 mV+5%. |
|
Gain Settings and Accuracy |
5 mm/mV (x0.5), 10 mm/mV (x1), 20 mm/mV (x2 ) shall be provided |
|
Input impedance |
≥5.0Ω |
|
Low Frequency Characteristics |
Time constant not less than 3.2 s |
|
oximetry |
sensors |
Dual Wavelength Light Emitting Diodes |
wave length |
Red light:663nm |
|
Infrared light:890nm |
||
Measurement Range |
35% to 100%; |
|
Maximum output power |
≤2mW |
|
measurement error |
The measurement error is ±2% in the range of 70% to 100%. |
|
Pulse rate measurement error |
30 to 250bpm The monitoring error is ±2bpm or ±%2, whichever is greatest. |
|
sphygmometer |
Display method |
Large LCD Digital |
Measurement method |
signal wave method |
|
Measurement Range |
Blood pressure:30~280mmHg |
|
Pulse rate:40 to 195 beats/min |
||
precision |
Pressure ±3mmHg |
|
Pulse rate number ±5% |
||
Pressurization / Pressure Relief |
Pressurization/decompression using a microelectronic air pump control system |
|
Storage function |
100 sets of measured values with date/time (no loss of memory) |
|
Suitable for arm circumference |
22cm to 32cm |
|
power supply |
DC 6V |
|
Use of temperature and humidity |
+5°C - +40°C RH ≤ 80% (measurement outside the range, measurement results have deviations) |
|
Preservation of temperature and humidity |
-20℃-+55℃ RH≤93% (measurement outside the range, measurement results have deviations) |
|
Operating atmospheric pressure |
525-795 mmHg |
|
Transport and storage atmospheric pressure |
375-795 mmHg |
|
A4 Printer Hewlett-Packard ( HP108A ) |
resolution (of a photo) |
B&W (best mode): up to 1,200x1,200dpi; B&W (normal mode): up to 600x600dpi |
Printer Language |
GDI (host-based language) |
|
Print speed |
B&W (normal mode, A4): up to 20 pages/min; B&W (long-edge feed, A5): up to 30 pages/min |
|
Print load |
Up to 10,000 pages |
|
First Print Time |
B&W (A4, ready mode): only 8.3 seconds; B&W (A4, sleep mode): as fast as 18 seconds |
|
weight |
4.18 kg |
|
interface |
High-speed USB 2.0 port |
|
System Parameters |
Windows:7(32/64 bit), 2008 Server R2,8(32/64 bit),8.1(32/64 bit),10(32/64 bit),2012 Server,2016 Server |
|
size |
331*215*178 mm |
|
RAM |
64 MB |
|
power supply |
Power supply type: built-in power supply; power requirements: 110 volts input voltage: 110 to 127 volts AC, 50/60 Hz; 220 volts input voltage: 220 to 240 volts AC, 50/60 Hz |
|
Blood sugar, uric acid, total cholesterol |
autopsy |
Fingertip microvascular whole blood |
Detection time |
Blood sugar:in 10 seconds Uric acid:in 15 seconds Total cholesterol:in 26 seconds |
|
Scope of testing |
Blood glucose:20-600mg/dL (1.1-33.3mmol/L) Uric acid:3-20mg/dL (0.18-1.19mmol/L) Total cholesterol:100-400mg/dL (2.59-10.35mmol/L) |
|
volume of the body to be examined |
Blood glucose 0.9uL, total cholesterol 10uL, uric acid 1uL |
|
Storage temperature |
10°C - 30°C |
|
Operating temperature |
10°C - 40°C |
|
relative humidity |
<95% |
|
Memory capacity |
Blood glucose 360 group, total cholesterol 50 group, uric acid 50 group |
|
Battery life |
Approx. 1000 measurements |
|
Data output interface |
LAN interface |
|
Supply voltage |
220 AC (50Hz/60Hz) |
|
rating |
(100W) Max. |
|
Operating humidity range (storage temperature range) |
5°C to 45°C (-10°C to +60°C) |
|
operating system |
Windows 7, 32-bit or above |