Touchscreens | size | 15.6 |
(body) temperature | Displaying the exact number of digits | 0.1 °C |
Body temperature measurement mode | 32.0 to 42.5°C | |
Object temperature measurement mode | 0 to 100°C | |
precision | ≤±0.3°C | |
power wastage | ≤120mw | |
measuring distance | 5 to 8 cm | |
automatic shutdown | About 15 seconds. | |
12-lead ECG | Collection method | 12-lead synchronized ECG Wilson |
Power input | d.c5.0V (powered by computer USB port) | |
Sampling frequency | 500Hz | |
Calibration voltage | Calibration voltage:1 mV+5%. | |
Gain Settings and Accuracy | 5 mm/mV (x0.5), 10 mm/mV (x1), 20 mm/mV (x2 ) shall be provided | |
Input impedance | ≥5.0Ω | |
Low Frequency Characteristics | Time constant not less than 3.2 s | |
oximetry | sensors | Dual Wavelength Light Emitting Diodes |
wave length | Red light:663nm | |
Infrared light:890nm | ||
Measurement Range | 35% to 100%; | |
Maximum output power | ≤2mW | |
measurement error | The measurement error is ±2% in the range of 70% to 100%. | |
Pulse rate measurement error | 30 to 250bpm The monitoring error is ±2bpm or ±%2, whichever is greatest. | |
sphygmometer | Display method | Large LCD Digital |
Measurement method | signal wave method | |
Measurement Range | Blood pressure:30~280mmHg | |
Pulse rate:40 to 195 beats/min | ||
precision | Pressure ±3mmHg | |
Pulse rate number ±5% | ||
Pressurization / Pressure Relief | Pressurization/decompression using a microelectronic air pump control system | |
Storage function | 100 sets of measured values with date/time (no loss of memory) | |
Suitable for arm circumference | 22cm to 32cm | |
power supply | DC 6V | |
Use of temperature and humidity | +5°C - +40°C RH ≤ 80% (measurement outside the range, measurement results have deviations) | |
Preservation of temperature and humidity | -20℃-+55℃ RH≤93% (measurement outside the range, measurement results have deviations) | |
Operating atmospheric pressure | 525-795 mmHg | |
Transport and storage atmospheric pressure | 375-795 mmHg | |
A4 Printer Hewlett-Packard ( HP108A ) | resolution (of a photo) | B&W (best mode): up to 1,200x1,200dpi; B&W (normal mode): up to 600x600dpi |
Printer Language | GDI (host-based language) | |
Print speed | B&W (normal mode, A4): up to 20 pages/min; B&W (long-edge feed, A5): up to 30 pages/min | |
Print load | Up to 10,000 pages | |
First Print Time | B&W (A4, ready mode): only 8.3 seconds; B&W (A4, sleep mode): as fast as 18 seconds | |
weight | 4.18 kg | |
interface | High-speed USB 2.0 port | |
System Parameters | Windows:7(32/64 bit), 2008 Server R2,8(32/64 bit),8.1(32/64 bit),10(32/64 bit),2012 Server,2016 Server | |
size | 331*215*178 mm | |
RAM | 64 MB | |
power supply | Power supply type: built-in power supply; power requirements: 110 volts input voltage: 110 to 127 volts AC, 50/60 Hz; 220 volts input voltage: 220 to 240 volts AC, 50/60 Hz | |
Blood sugar, uric acid, total cholesterol | autopsy | Fingertip microvascular whole blood |
Detection time | Blood sugar:in 10 seconds Uric acid:in 15 seconds Total cholesterol:in 26 seconds | |
Scope of testing | Blood glucose:20-600mg/dL (1.1-33.3mmol/L) Uric acid:3-20mg/dL (0.18-1.19mmol/L) Total cholesterol:100-400mg/dL (2.59-10.35mmol/L) | |
volume of the body to be examined | Blood glucose 0.9uL, total cholesterol 10uL, uric acid 1uL | |
Storage temperature | 10°C - 30°C | |
Operating temperature | 10°C - 40°C | |
relative humidity | <95% | |
Memory capacity | Blood glucose 360 group, total cholesterol 50 group, uric acid 50 group | |
Battery life | Approx. 1000 measurements | |
Data output interface | LAN interface | |
Supply voltage | 220 AC (50Hz/60Hz) | |
rating | (100W) Max. | |
Operating humidity range (storage temperature range) | 5°C to 45°C (-10°C to +60°C) | |
operating system | Windows 7, 32-bit or above |