Project name
|
Parameter
|
Specification
|
Machine parameters
|
Data output interface
|
LAN network port*1 USB*2
|
Power supply
|
100Vï½240Vï¼50/60Hz
|
|
Power rating
|
ï¼100Wï¼Maximum
|
|
LCD screen
|
21.5inch
|
|
ID card reader
|
||
Operating humidity range (storage temperature range)
|
5âï½45âï¼-10âï½+60âï¼
|
|
Operating System
|
Windows 10 (More than 32)
|
|
Data Transmission Mode
|
internet accessãWIFI
|
|
Overall Dimension
|
1800(lengthï¼*1200ï¼ Widthï¼*2450ï¼height ï¼mm
|
|
Weight
|
About 220KG
|
|
Height
|
Measuring system
|
Ultrasonic measurement (high precision temperature difference compensation)
|
Measuring range
|
70.0ï½205cm
|
|
Permissible error
|
±0.5cm
|
|
Weight
|
Measuring system
|
Precision balance beam pressure sensor weighing
|
BMI
|
The automatic intelligence calculates the body mass index
|
|
Measuring range
|
1ï½300kg
|
|
Permissible error
|
±0.1kg
|
|
Body fat
|
Measuring frequency
|
Multi frequency 4- electrode
|
Electrode material
|
Electroplating material
|
|
Measuring range
|
200ï½1000Ω
|
|
Body temperature (DT-8836)
|
Display exact number
|
0.1 â
|
Human body temperature measurement
|
32.0ï½42.5â
|
|
Object temperature measurement
|
0ï½100â
|
|
Accuracy
|
â¤Â±0.3â
|
|
Power Consumption
|
â¤120mw
|
|
Measuring distance
|
5-8cm
|
|
Auto Power -Off
|
About 15 second
|
|
Blood pressureï¼RBP-7000ï¼
|
Display
|
Digital display
|
Measuring method
|
Oscillographic method
|
|
Measuring range
|
Pressure (0~300) mmHg [ (0~ 40)kPa]
rate 30/minute~200/minute |
|
Accuracy
|
Pressure 士2mmHg(士0.267kPa)within
Rate士2% within |
|
Screen
|
LCD screen
|
|
Data Transmission Mode
|
232 port/USB
|
|
Power Supply
|
Power Adapterï¼Input AC100V~240V,50/60Hz,Output DC12V,3.5Aï¼
|
|
Operating temperature and humidity
|
5âï½40âï¼15%RHï½80%RH
|
|
Transport and storage temperature and humidity
|
-20âï½+55âï¼â¤93%RH
|
|
Operating atmospheric pressure
|
80kPaï½106kPa
|
|
Transport and storage atmospheric pressure
|
50kPaï½106kPa
|
|
Overall dimensions
|
387.7mmï¼Lï¼Ã244.1mmï¼Wï¼Ã340.2mmï¼Hï¼
|
|
Net Weight
|
About 6.0Kg
|
|
Cuff applies to perimeter range
|
17cmï½42cm
|
|
Blood oxygen KS-CM01
|
Sensor
|
Dual wavelength light emitting diode
|
Wavelength
|
Red Lightsï¼663nm
|
|
Infrared lightï¼890nm
|
||
Measuring range
|
35%ï½100%;
|
|
Maximum average optical Output power
|
â¤2mW
|
|
Permissible error
|
The measurement error was ±2% in the range of 70% to 100%
|
|
Pulse rate measurement error
|
Tolerance of 30-250bpm was ±2bpm or ±%2, which was the maximum
|
|
Single lead ECG
|
Operating temperature
|
5âï½40â
|
Environment temperature
|
30%ï½80% Non - Condensing
|
|
Range of atmospheric Pressure
|
70KPaï½106KPa
|
|
Heart rate measurement range
|
30bpmï½240bpm
|
|
Accuracy of heart rate Measurement
|
The maximum value is ± 2BPM or ±2
|
|
Waveform display sensitivity
|
5.0mm/mv error±10%
|
|
Scanning speed
|
20mm/s error±10%
|
|
Input impedance
|
â¥5.0Ω
|
|
Operating voltage
|
d.c.2.5V±0.2V
|
|
Blood sugar, uric acid, total cholesterol
ï¼BeneCheck BKM13-1ï¼ |
Specimens
|
Whole fingertip micro-vascular blood
|
Detection time
|
Blood sugar 10 seconds; uric acid 15 seconds; total cholesterol 26 seconds
|
|
Measuring range
|
blood glucoseï¼20-600mg/dL (1.1-33.3mmol/L)
Uric Acidï¼3-20mg/dLï¼0.18-1.19mmol/Lï¼ Total cholesterolï¼100-400mg/dLï¼2.59-10.35mmol/Lï¼ |
|
Liquid volume inspector
|
blood glucose 0.9uL,Total cholestero l10uL, Uric Acid 1uL
|
|
Storage Temperature
|
10â-30â
|
|
Operating Temperature
|
10â-40â
|
|
Relative humidity
|
ï¼95%
|
|
Memory capacity
|
Blood glucose 360 group, total cholesterol 50 group, uric acid 50 group
|
|
Battery type
|
A 3V (CR2032) button lithium battery
|
|
Validity of battery
|
About 1000 tests
|
|
Camera
|
Pixels
|
5 million
|
Port
|
USB 2.0
|
|
Driver
|
free drive
|
|
Thermal printerï¼SP-EU58ï¼
|
Printing method
|
Line thermal printing
|
Printing paper
|
(straight roll) Heat sensitive 57.5mmà paper roll 100mm (MAX)
|
|
Carriage Paper Width
|
57.5±0.5 mm
|
|
Effective print width
|
48mm
|
|
Image resolution
|
8 /mmï¼203dpï¼
|
|
Printing speed
|
Max 80mm/Sï¼No more than 25% print points per lineï¼
|
|
Paper thickness
|
0.06~0.08 mm
|
|
Print head span
|
50KM
|
|
Operating ambient temperature/humidity
|
0-50â/10-80%
|
|
Temperature/humidity of the storage environment
|
-20-60â/10-90%
|
Copyright © - Privacy policy