Features &Benefits: |
||
1. 12.1â color TFT display, high resolution: 800Ã600dpi; |
||
2. Separated para board: ECG, NIBP, SpO2 board; |
||
3. Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation knob. |
||
4. Real time S-T segment analysis, and ARR analysis; |
||
5. SpO2 Pitch Tone Variation and Drug Dose Calculation; |
||
6. Parameter waveform and characters color selectable |
||
7. Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic |
||
8. Standby mode for Energy saving and suspend monitoring; |
||
9. 7-lead ECG waveforms display in phase; |
||
10. Capture dynamic waveforms; |
||
11. Built-in rechargeable lithium battery, and battery volume checking, |
||
12. AC power checking |
||
13. Efficient resistance to interference of defibrillator and HF knife; |
||
14. SINNOR F-6 SpO2 technology, VS NELLCOR accuracy; |
||
15. Networking capacity and TCP/IP networking platform enable abundant future upgrade |
||
16. Time delay switch-off function keep the monitor data restart monitor; |
||
17. Complete and flexible mounting solution for transportation and in-patient monitoring |
||
Standard parameters: 5-lead ECG, SpO2(F-5),NIBP, TEMP,RESP,PR,HR. |
||
Optional: Touch Screen, Thermal Recorder, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-SpO2, Nellcor/Masimo SpO2,BIS, Phaisein/ Respironics Multi-gas, ICG/CO, FHR, FM, TOCO, |
||
Performance Specifications |
||
Display: |
12.1âcolor TFT |
|
Rolling and refreshing waveform display |
||
Resolution: 800Ã600 |
||
Multi display selectable including: |
||
Large-font display |
||
Trend coexist display |
||
OxyCRG dynamic view display. |
||
Bed-to-bed view display |
||
Trace: |
9 waveforms(7 ECG, 1 SPO2 and 1 RESP) |
|
Sweep speed:12.5mm/s,25mm/s,50mm/s |
||
Indicator: |
Power/battery indicator light |
|
QRS beep and alarm sound |
||
Battery: |
Rechargeable lead acid cell, 12v/4AH |
|
Max.24 hour for charging, 4 hours for continue working |
||
Trend: |
Parameter graphic and tabular trends: |
|
5s/piece,8 hours; |
||
1min/piece,168 hours(24hourÃ7days) |
||
5min/piece,1000 hours. |
||
Storage: |
NIBP: 1000 groups |
|
Alarm: 200 groups |
||
Full disclosure waveforms: 3600S |
||
SD card external storage |
||
Alarm: |
User-adjustable High, Medium and Low limits 3-level |
|
Audible and visual alarm |
||
Networking: |
Connected to central monitoring system |
|
TCP/IP netting platform |
||
Recorder: |
Build-in, thermal array |
|
Plethysmogram caveform:2 channels |
||
Record mode: manual, on alarm, time-defined |
||
Recording width: 50mm |
||
Printing speed: 50mm/s |
||
Recording type: |
Frozen waveform record |
|
NIBP recall record |
||
Trend table record |
||
Alarm record |
||
Fixed -time record |
||
Standard parameter: |
||
ECG: |
||
Lead mode: |
5 âlead(R,L,F,N,C) |
|
Lead selection : |
I,II,III,avR,avL,avF,V |
|
Waveform: |
3 and 7 channel selectable |
|
Gain selection: |
0.5mm/mv,1mm/mv,2mm/mv |
|
Sweep speed: |
12.5mm/s;25mm/s;50mm/s |
|
Heart rate range: |
Adult: 15~300bpm; |
|
Neonate/pediatric:15~350bpm |
||
Accuracy: |
+1bpm or +1%,whichecer is greater |
|
Resolution: |
1bpm |
|
Filter: |
surgery mode:1~20Hz |
|
monitor model:0.5~40Hz |
||
Diagnostic mode:0.05~130Hz |
||
Scaling signal: |
1mv,+3% |
|
Protection: |
withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation |
|
Alarm range: |
15~350bpm |
|
S-T segment detecton: |
||
Measurement range: |
2.0mV~+2.0mV |
|
Alarm Range: |
-2.0mV~ +2.0mV |
|
Accuracy: |
-0.8mV ~+0.8Mv |
|
Error: |
+0.02Mv |
|
Arrhythmia analysis: |
YES |
|
SPO2 |
||
Measurement range: |
0~100% |
|
Resolution: |
1% |
|
Accuracy: |
+2%(70-100%);0-69% unspecified |
|
Alarm range |
0~100% |
|
Pluse Rate range: |
20~300bpm |
|
Error: |
+1bpm or +2%,whichever is greater |
|
NIBP |
||
Method: |
Digital Automatic oscillometric |
|
Operation mode : |
Manual/Automatic/continuous |
|
Auto measurement time: |
Adjustable(1~480min) |
|
Measurement Unit: |
mmHg/Kpa selectable |
|
Measurement types: |
Systolic, Diastolic, Mean |
|
Measurement tange: |
||
Range of Systolic pressure |
Adult: 40~270mmHg |
|
Pediatric: 40~220mmHg |
||
Neonate: 40~135mmHg |
||
Range of mean pressure: |
Adult: 20~235mmHg |
|
Pediatric: 20~165mmHg |
||
Neonate: 20~110mmHg |
||
Range of diastolic pressure: |
Adult: 10~215mmHg |
|
Pediatric: 10~150mmHg |
||
Neonate :10~100mmHg |
||
Over-pressure protection: |
Double safety protection |
|
Resolution: |
1 mmHg |
|
Alarm |
Systolic.Diastolic,Mean |
|
RESPIRATION |
||
Method: |
Thoracic impedance |
|
Measurement range: |
Adult:7~120rpm; Neonate/Pediatric:7~150rpm |
|
Apnea alarm: |
YES,10~40s |
|
Resolution: |
1rpm |
|
Accuracy: |
+2rpm |
|
TEMPERATURE |
||
Compatible probe: |
YSI or CYF +0.1â |
|
Measurement range: |
5~50â |
|
Resolution : |
0.1â |
|
Accuracy: |
+0.1â |
|
Refreshing time: |
about 1 |
|
Average measuring time: |
<10s |
|
FHR |
||
Transducer: |
Multi-crystal, Pulsed Doppler |
|
Measurement range: |
50~210 BPM |
|
Working frequency: |
1 MHz |
|
Strength: |
<5mW/cm[] |
|
Signal processing: |
special DSP system and modern recognization. |
|
Resolution: |
1BPM |
|
Accuracy: |
±1BPM |
|
Alarm Range: |
High: 160,170,180,190 BPM, Low: 100,110,120 BPM |
|
FM |
||
Manual button marking, |
||
automatic FM identifying function |
||
TOCO Measuring |
||
Transducer: External pressure transducer |
||
Measurement range: 0~100 units |
||
Resolution: 1rpm |
||
Accuracy: ±2 rpm |
||
IBP |
||
Channel: 2 channels |
||
Range: ï¼50-300mmHg |
||
Resolution: 1mmHg |
||
Accuracy: ±4mmHg(±4%) |
||
Unit: mmHg, Kpa |
||
Converter Sensitivity: 5V/V/mmHg |
||
Transducer sites: ART/PA/CVP/LAP/RAP/ICP |
||
EtCO2( Sidertream CO2) |
||
Measurement range: 0~99mmHg |
||
Accuracy: +2mmHg (0~40mmHg) |
||
Sampling Range: 100ml/min |
||
Sampling rate accuracy: 15% |
||
Respiration rate: 0~120rmp |
||
Respiration accuracy: +2rmp (0~70rmp) |
||
+5rmp (>70rmp) |
||
Respiration time: <240msec (10% to 90%) |
||
Delay time: <2s |
||
EtCO2 (mainstreaam CO2) |
||
Method: Infrared Spectrum |
||
Range: 0.0-10% (0~76%) |
||
Resolution: 1mmHg (0.1%) |
||
Accuracy: ï¼5%(±4.0 mmHg) Orï¼10%(of Readings) |
||
Recorder: |
||
Build-in, thermal array |
||
Plethysmogram caveform:2 channels |
||
Record mode: manual, on alarm, time-defined |
||
Recording width: 50mm |
||
Printing speed: 50mm/s |
||
Recording type: Frozen waveform record NIBP recall record Trend table record Alarm record Fixed -time record |