Type | SK-X60HD |
Measurement range | Heightï¼50-200cm (±0.5cm) Weightï¼1.0-300kg(±0.1kg) |
Testing range | Body fatï¼5-50.0% BMIï¼2.5-90.0 Basal metabolismï¼385-5000kcal Humidity: 30-85%RH |
Temperature testing range | 32.5â-42.5â |
Working temperature | 10â-40â |
Blood oxygen testing | >95%(SPO2) |
Blood pressure | 0ï½299mmHg, 40pluse/minï½240pluse/min |
Touch screen | 21inch LCD screen |
Data Output Interface | TCP/IP |
API | Provided |
Voltage | 110-240V |
Operating humidity range | 5âï½45â |
Package dimension | 184*121*75cm |
Net Weight/Package weight | 85KG/130kg |
Model No. | SK-X60HD | ||
Class | Category â
Grade B | ||
Body weight measurement | Measuring system | Resistance strain gauge load cell | |
Configured body weight | Sonka body weight | ||
Range of measurement | 500kg | ||
Verified precision | ±0.1kg | ||
Height measurement | Measuring system | Ultrosonic probe | |
Configured body height | Sonka body height | ||
Range of measurement | 70.0ï½200cm | ||
Verified precision | 0.1cm | ||
Blood pressure measurement | Model | Raycome, RBP-7000 | |
Display | LCD Digital Display | ||
Measurement Method | Oscillometric method | ||
Measurement Range | Pressure: 0 mmHg to 299 mmHg, Pulse: 40 to 180/min. | ||
Accuracy | Pressure: ±3 mmHg, Pulse: ± 5% | ||
Inflation | Electric pump | ||
Deflation | Automatic pressure release valve | ||
Pressure Detection | Capacitive pressure sensor | ||
Memory | 84 Measurements with date and time for each user(A and B) | ||
AC/DC adapter | Input 100-240V 50Hz/60Hz,Output 6V/9.6W | ||
Storage temperature/Humidity/Air Pressure | -20°C to 60°C/10 to 95% RH700 - 1060 hPa | ||
Weight | Approximately 2600 g | ||
Dimensions | Approximately 286 (l) mm * 294 (w) mm * 271 (h) mm | ||
Arm Circumference | 22 to 42 cm | ||
Measurement of Fat | Measuring system | Multi-frequency 4- Electrode | |
Measurement frequency | 5kHz/50kHz/250kHz/500kHz | ||
Measurement category | "Body fat, visceral fat, body water, muscle, bone mass, basal metabolism" | ||
Material | Electroplating material | ||
Current for measurement | 90μA or below | ||
Range of measurement | 75.0ï½1,500.00Ω (0.1ΩUnit) | ||
Measurement of blood oxygen | Blood oxygen probe | CREATIVE KS-CM01 | |
Sensor | Dual wavelength LED | ||
Wavelength | Visible light( Max)ï¼663nm, Invisible Lightï¼890nm | ||
Measurement range | 35%ï½100% | ||
Average output power (Max) | â¤2mW | ||
Measurement error | In the range of 70% to 100% < ±2% | ||
Accuracy | In the range of 70% to 100% < ±3% | ||
Pulse rate measurement error | 30ï½250bpm (Monitoring error is ±2bpm or ±%2, whichever is the largest) | ||
Working humidity | 5âï½40â | ||
Relative Humidity | 15%ï½95%ï¼Non-condensingï¼ | ||
Atmospheric pressure | 70kpaï½106kpa | ||
Power supply mode | Powered by ancillary equipment | ||
Range of measurement | 95-99%ï¼Â±2%normal status,±3% motion or weak perfusion,less than 95% undefinedï¼ | ||
Body temperature | Infrared thermometer | Calibeur DT-8836 | |
Accuracy | 0.1 â | ||
Operating Temperature | 10ï½40â | ||
Storage temperature | 0ï½50â | ||
Relative humidity | â¤85% | ||
Power supply | DC 9Vï¼6F22:a layer-built batteryï¼ | ||
Dimensions | 150*75*40mm | ||
Weight | Gross weight: 400g, Net weight: 172g | ||
Measurement range | 32.0ï½42.5â | ||
Object temperature range | 0ï½100â | ||
Accuracy | 5âï½40â | ||
Power dissipation | â¤120mw | ||
Measurement distance | 5-8cm | ||
Auto power off | About 15 seconds | ||
Touch display | Display screen | "21âimported color LCD panel, response speed:6ms, bearing a super height of 1500nits, Visible LCD Screen under sunlight." | |
Temperature and humidity | Temperature:0--50â;Humidity:10%--90%ï¼Relative,non-compactï¼ | ||
Resolution rate | 800*600 / 32bit true color | ||
Brightness and Contrast | 400cd/ã¡ ; 5000:1 | ||
Average trouble-free time of touch panels | Industrial-grade Resistance Touch Panel,more than 20 thousand hours of trouble-free operation; | ||
Life endurance of touch panel | More than 30 million times of trouble-free operationï¼Tip R0.8mmï¼ | ||
Data output port | LAN network port | ||
Power voltage | 100-240 AC (50Hz/60Hz) | ||
Rated power | ï¼100Wï¼Max. | ||
Temperature of operation/Storage | 5âï½45âï¼-10âï½+60âï¼ | ||
Computer | Brand: GIFA industrial control, Intel dual core processor |