Project name |
Parameter |
Specification |
Machine parameters |
Data output interface |
LAN network port*1 USB*2 |
Power supply |
100V~240V,50/60Hz |
|
Power rating |
(100W)Maximum |
|
LCD screen |
21.5inch |
|
ID card reader |
||
Operating humidity range (storage temperature range) |
5℃~45℃(-10℃~+60℃) |
|
Operating System |
Windows 10 (More than 32) |
|
Data Transmission Mode |
internet access、WIFI |
|
Overall Dimension |
1800(length)*1200( Width)*2450(height )mm |
|
Weight |
About 220KG |
|
Height |
Measuring system |
Ultrasonic measurement (high precision temperature difference compensation) |
Measuring range |
70.0~205cm |
|
Permissible error |
±0.5cm |
|
Weight |
Measuring system |
Precision balance beam pressure sensor weighing |
BMI |
The automatic intelligence calculates the body mass index |
|
Measuring range |
1~300kg |
|
Permissible error |
±0.1kg |
|
Body fat |
Measuring frequency |
Multi frequency 4- electrode |
Electrode material |
Electroplating material |
|
Measuring range |
200~1000Ω |
|
Body temperature (DT-8836) |
Display exact number |
0.1 ℃ |
Human body temperature measurement |
32.0~42.5℃ |
|
Object temperature measurement |
0~100℃ |
|
Accuracy |
≤±0.3℃ |
|
Power Consumption |
≤120mw |
|
Measuring distance |
5-8cm |
|
Auto Power -Off |
About 15 second |
|
Blood pressure(RBP-7000) |
Display |
Digital display |
Measuring method |
Oscillographic method |
|
Measuring range |
Pressure (0~300) mmHg [ (0~ 40)kPa] rate 30/minute~200/minute |
|
Accuracy |
Pressure 士2mmHg(士0.267kPa)within Rate士2% within |
|
Screen |
LCD screen |
|
Data Transmission Mode |
232 port/USB |
|
Power Supply |
Power Adapter(Input AC100V~240V,50/60Hz,Output DC12V,3.5A) |
|
Operating temperature and humidity |
5℃~40℃,15%RH~80%RH |
|
Transport and storage temperature and humidity |
-20℃~+55℃,≤93%RH |
|
Operating atmospheric pressure |
80kPa~106kPa |
|
Transport and storage atmospheric pressure |
50kPa~106kPa |
|
Overall dimensions |
387.7mm(L)×244.1mm(W)×340.2mm(H) |
|
Net Weight |
About 6.0Kg |
|
Cuff applies to perimeter range |
17cm~42cm |
|
Blood oxygen KS-CM01 |
Sensor |
Dual wavelength light emitting diode |
Wavelength |
Red Lights:663nm |
|
Infrared light:890nm |
||
Measuring range |
35%~100%; |
|
Maximum average optical Output power |
≤2mW |
|
Permissible error |
The measurement error was ±2% in the range of 70% to 100% |
|
Pulse rate measurement error |
Tolerance of 30-250bpm was ±2bpm or ±%2, which was the maximum |
|
Single lead ECG |
Operating temperature |
5℃~40℃ |
Environment temperature |
30%~80% Non - Condensing |
|
Range of atmospheric Pressure |
70KPa~106KPa |
|
Heart rate measurement range |
30bpm~240bpm |
|
Accuracy of heart rate Measurement |
The maximum value is ± 2BPM or ±2 |
|
Waveform display sensitivity |
5.0mm/mv error±10% |
|
Scanning speed |
20mm/s error±10% |
|
Input impedance |
≥5.0Ω |
|
Operating voltage |
d.c.2.5V±0.2V |
|
Blood sugar, uric acid, total cholesterol (BeneCheck BKM13-1) |
Specimens |
Whole fingertip micro-vascular blood |
Detection time |
Blood sugar 10 seconds; uric acid 15 seconds; total cholesterol 26 seconds |
|
Measuring range |
blood glucose:20-600mg/dL (1.1-33.3mmol/L) Uric Acid:3-20mg/dL(0.18-1.19mmol/L) Total cholesterol:100-400mg/dL(2.59-10.35mmol/L) |
|
Liquid volume inspector |
blood glucose 0.9uL,Total cholestero l10uL, Uric Acid 1uL |
|
Storage Temperature |
10℃-30℃ |
|
Operating Temperature |
10℃-40℃ |
|
Relative humidity |
<95% |
|
Memory capacity |
Blood glucose 360 group, total cholesterol 50 group, uric acid 50 group |
|
Battery type |
A 3V (CR2032) button lithium battery |
|
Validity of battery |
About 1000 tests |
|
Camera |
Pixels |
5 million |
Port |
USB 2.0 |
|
Driver |
free drive |
|
Thermal printer(SP-EU58) |
Printing method |
Line thermal printing |
Printing paper |
(straight roll) Heat sensitive 57.5mm× paper roll 100mm (MAX) |
|
Carriage Paper Width |
57.5±0.5 mm |
|
Effective print width |
48mm |
|
Image resolution |
8 /mm(203dp) |
|
Printing speed |
Max 80mm/S(No more than 25% print points per line) |
|
Paper thickness |
0.06~0.08 mm |
|
Print head span |
50KM |
|
Operating ambient temperature/humidity |
0-50℃/10-80% |
|
Temperature/humidity of the storage environment |
-20-60℃/10-90% |
Telemedicine Kiosk: |
SK-T9 |
|
Height |
Height sensor |
Ultrasound probe(Buy from USA) |
Range |
70.0~200cm |
|
Accuracy |
0.01cm |
|
Weight |
BMI |
Automatic calculation |
Loadcell |
500kg |
|
Accuracy |
±0.1kg |
|
Body composition analysis |
Frequencies |
5kHz/50kHz/250kHz/500kHz |
Measurement |
Body fat, visceral fat, body water, muscle, bone mass, basal metabolism |
|
Measurement current |
90μA or below |
|
Electrode material |
Electroplating material |
|
Measurement range |
75.0~1,500.00Ω(0.1Ω unit) |
|
Measurement location |
Trunk, 4 limbs |
|
Body temperature |
Test method |
Infrared wireless hand-held temperature gun |
Accurate to |
0.1 ℃ |
|
Operation & storage temperature |
10~40℃, 0~50℃ |
|
Operation & storage humidity |
≤85% |
|
Power |
DC 9V |
|
Dimension |
150*75*40mm |
|
Weight |
180g |
|
Human temperature range |
32.0~42.5℃ |
|
Object temperature range |
0~100℃ |
|
Accuracy |
≤±0.3℃ |
|
Power consumption |
≤120mw |
|
Detection distance |
5 to 8 cm |
|
Auto-off |
after 15 seconds |
|
Blood pressure monitor |
Blood pressure range |
(0~270)mmHg,[(0~36)Kpa] Pulse rate: 40-180bpm |
Storage capacity |
100 pcs of record |
|
Accuracy |
Blood pressure: <±2mmHg(±0.267kpa) |
|
Pulse: <±2% |
||
Power |
AC 100-240V,50-60Hz,1.6-0.8A |
|
Operation temperature & humidity |
5℃~40℃ 15%RH~80%RH |
|
Transport & storage temperure & humidity |
-20℃~55℃ <93%RH |
|
Operation atmospheric pressure |
80Kpa~106Kpa |
|
Transport & storage atmospheric pressure |
50Kpa~106Kpa |
|
Dimension |
471.5mm(L)*402.0mm(W)*309.0mm(H) |
|
Electric shock protection |
Class I, type B |
|
Device weight |
8kg |
|
Arm circumference |
17-42cm |
|
Blood oxygen |
Probe |
Dual-wavelength LED |
Wave length |
Red light: 663nm, Infrared: 890nm |
|
Range |
35%~100% |
|
Power of maximum light output |
≤2mW |
|
Blood oxygen rate accuracy |
Range: 70%~100%, ±2% |
|
Pulse rate accuracy |
Range: 30~250bpm, ±2% |
|
Operation temperature |
5℃~40℃ |
|
Operation humidity |
15%~95% |
|
Atmospheric pressure |
70kpa~106kpa |
|
Power input |
From main device by RS232 |
|
ECG |
Leads |
6 or 12 leads |
Collection |
Syhchronization |
|
Calibration voltage |
1mV±5% |
|
Polarization resistance voltage |
±300mV |
|
Sensitivity |
5, 10, 20(mm/mV) |
|
Input impedance |
≥5MΩ |
|
Input loop current |
<0.05uA |
|
Heart rate range |
20-300bmp/min |
|
Noise level |
≤15uVp-p |
|
Filtering |
EMG Filtering |
|
Baseline filtering |
||
AC filtering |
||
Common mode rejection ratio |
>90dB |
|
Time constant |
≥3.2s |
|
Frequency response |
0.05Hz~150Hz(-3.0dB/+0.4dB) |
|
Rhythmic lead |
Any leads optional |
|
Base line adjustment |
Automatic |
|
Patient leak current |
<10uA(220V-240V) |
|
Patient auxiliary current |
≤0.1uA(DC) |
|
Safety standard |
IEC II/CF |
|
Sampling frequency |
500Hz |
|
Electrode |
Chest electrodes and limb electrodes adopt international colors, each matches different color |
|
Blood glucose Uric acid Total cholesterol |
Measurement range |
Blood glucie: 1.1-33.3mmol/L(20-600mg/dL) Uric acid: 0.18-1.19mmol/L(3-20mg/dL) cholesterol: 2.59-10.35mmol/L(100-400mg/dL) |
Measurement time |
blood glucoe: 5s±0.5s Uric acid: 15S±0.5S Total cholesterol: 26S±0.5S |
|
Reference for normal |
Blood glucose before meal: 3.9mmol/L-6.1 mmol/L Blood glucose after 2 hours of meal: <7.8 mmol/L |
|
Uric acid of male: 0.21~0.43mmol/L |
||
Uric acid of female: 0.16~0.36mmol/ |
||
Uric acid of children: 0.12~0.33mmol/L |
||
Total cholesterol: 2.86~5.98mmol/L |
||
Accuracy |
±0.3(test by standard resistance slip) |
|
Display |
mmol/Lx and time display |
|
Inbuilt battery |
3V Lithium battery |
|
Blood glucose |
Sample type |
Capillary vessel whole blood sample |
Mesurement range |
10-600 mg/dL(0.6-33.3mmol/L) |
|
Sample volumn |
0.3 microlitre |
|
Test period |
3 seconds |
|
Calibration |
Plasma or similar product |
|
HCT range |
20-60% |
|
RFID |
Standard: IS0/IEC 15693 |
|
Read/write distance: 2cm |
||
Antenna: integrated |
||
Frequence: 13.56MHz |
||
Measurement theory for blood glucose |
Electrochemistry, Optical spectrum |
|
Storage capacity |
200 |
|
Operation temperature |
Lipid profile: 18-30℃(64-86℉) Blood glucose: 10-40℃ (50-104℉) |
|
Operation humidity |
10-90% |
|
Storage temperature |
2-30℃(36-80℉) |
|
Display |
LCD |
|
Dimension |
61*109*23(mm) |
|
Weight |
77.5(with battery)±1g |
|
Battery life time |
>1000 cycle use |
Copyright © - Privacy policy