Project name | Parameter | Specification |
Machine parameters | Data output interface | LAN network port*1 USB*2 |
Power supply | 100V~240V,50/60Hz | |
Power rating | (100W)Maximum | |
LCD screen | 21.5inch | |
ID card reader | ||
Operating humidity range (storage temperature range) | 5℃~45℃(-10℃~+60℃) | |
Operating System | Windows 10 (More than 32) | |
Data Transmission Mode | internet access、WIFI | |
Overall Dimension | 1800(length)*1200( Width)*2450(height )mm | |
Weight | About 220KG | |
Height | Measuring system | Ultrasonic measurement (high precision temperature difference compensation) |
Measuring range | 70.0~205cm | |
Permissible error | ±0.5cm | |
Weight | Measuring system | Precision balance beam pressure sensor weighing |
BMI | The automatic intelligence calculates the body mass index | |
Measuring range | 1~300kg | |
Permissible error | ±0.1kg | |
Body fat | Measuring frequency | Multi frequency 4- electrode |
Electrode material | Electroplating material | |
Measuring range | 200~1000Ω | |
Body temperature (DT-8836) | Display exact number | 0.1 ℃ |
Human body temperature measurement | 32.0~42.5℃ | |
Object temperature measurement | 0~100℃ | |
Accuracy | ≤±0.3℃ | |
Power Consumption | ≤120mw | |
Measuring distance | 5-8cm | |
Auto Power -Off | About 15 second | |
Blood pressure(RBP-7000) | Display | Digital display |
Measuring method | Oscillographic method | |
Measuring range | Pressure (0~300) mmHg [ (0~ 40)kPa] rate 30/minute~200/minute | |
Accuracy | Pressure 士2mmHg(士0.267kPa)within Rate士2% within | |
Screen | LCD screen | |
Data Transmission Mode | 232 port/USB | |
Power Supply | Power Adapter(Input AC100V~240V,50/60Hz,Output DC12V,3.5A) | |
Operating temperature and humidity | 5℃~40℃,15%RH~80%RH | |
Transport and storage temperature and humidity | -20℃~+55℃,≤93%RH | |
Operating atmospheric pressure | 80kPa~106kPa | |
Transport and storage atmospheric pressure | 50kPa~106kPa | |
Overall dimensions | 387.7mm(L)×244.1mm(W)×340.2mm(H) | |
Net Weight | About 6.0Kg | |
Cuff applies to perimeter range | 17cm~42cm | |
Blood oxygen KS-CM01 | Sensor | Dual wavelength light emitting diode |
Wavelength | Red Lights:663nm | |
Infrared light:890nm | ||
Measuring range | 35%~100%; | |
Maximum average optical Output power | ≤2mW | |
Permissible error | The measurement error was ±2% in the range of 70% to 100% | |
Pulse rate measurement error | Tolerance of 30-250bpm was ±2bpm or ±%2, which was the maximum | |
Single lead ECG | Operating temperature | 5℃~40℃ |
Environment temperature | 30%~80% Non - Condensing | |
Range of atmospheric Pressure | 70KPa~106KPa | |
Heart rate measurement range | 30bpm~240bpm | |
Accuracy of heart rate Measurement | The maximum value is ± 2BPM or ±2 | |
Waveform display sensitivity | 5.0mm/mv error±10% | |
Scanning speed | 20mm/s error±10% | |
Input impedance | ≥5.0Ω | |
Operating voltage | d.c.2.5V±0.2V | |
Blood sugar, uric acid, total cholesterol (BeneCheck BKM13-1) | Specimens | Whole fingertip micro-vascular blood |
Detection time | Blood sugar 10 seconds; uric acid 15 seconds; total cholesterol 26 seconds | |
Measuring range | blood glucose:20-600mg/dL (1.1-33.3mmol/L) Uric Acid:3-20mg/dL(0.18-1.19mmol/L) Total cholesterol:100-400mg/dL(2.59-10.35mmol/L) | |
Liquid volume inspector | blood glucose 0.9uL,Total cholestero l10uL, Uric Acid 1uL | |
Storage Temperature | 10℃-30℃ | |
Operating Temperature | 10℃-40℃ | |
Relative humidity | <95% | |
Memory capacity | Blood glucose 360 group, total cholesterol 50 group, uric acid 50 group | |
Battery type | A 3V (CR2032) button lithium battery | |
Validity of battery | About 1000 tests | |
Camera | Pixels | 5 million |
Port | USB 2.0 | |
Driver | free drive | |
Thermal printer(SP-EU58) | Printing method | Line thermal printing |
Printing paper | (straight roll) Heat sensitive 57.5mm× paper roll 100mm (MAX) | |
Carriage Paper Width | 57.5±0.5 mm | |
Effective print width | 48mm | |
Image resolution | 8 /mm(203dp) | |
Printing speed | Max 80mm/S(No more than 25% print points per line) | |
Paper thickness | 0.06~0.08 mm | |
Print head span | 50KM | |
Operating ambient temperature/humidity | 0-50℃/10-80% | |
Temperature/humidity of the storage environment | -20-60℃/10-90% |
Telemedicine Kiosk: | SK-T9 | |
Height | Height sensor | Ultrasound probe(Buy from USA) |
Range | 70.0~200cm | |
Accuracy | 0.01cm | |
Weight | BMI | Automatic calculation |
Loadcell | 500kg | |
Accuracy | ±0.1kg | |
Body composition analysis | Frequencies | 5kHz/50kHz/250kHz/500kHz |
Measurement | Body fat, visceral fat, body water, muscle, bone mass, basal metabolism | |
Measurement current | 90μA or below | |
Electrode material | Electroplating material | |
Measurement range | 75.0~1,500.00Ω(0.1Ω unit) | |
Measurement location | Trunk, 4 limbs | |
Body temperature | Test method | Infrared wireless hand-held temperature gun |
Accurate to | 0.1 ℃ | |
Operation & storage temperature | 10~40℃, 0~50℃ | |
Operation & storage humidity | ≤85% | |
Power | DC 9V | |
Dimension | 150*75*40mm | |
Weight | 180g | |
Human temperature range | 32.0~42.5℃ | |
Object temperature range | 0~100℃ | |
Accuracy | ≤±0.3℃ | |
Power consumption | ≤120mw | |
Detection distance | 5 to 8 cm | |
Auto-off | after 15 seconds | |
Blood pressure monitor | Blood pressure range | (0~270)mmHg,[(0~36)Kpa] Pulse rate: 40-180bpm |
Storage capacity | 100 pcs of record | |
Accuracy | Blood pressure: <±2mmHg(±0.267kpa) | |
Pulse: <±2% | ||
Power | AC 100-240V,50-60Hz,1.6-0.8A | |
Operation temperature & humidity | 5℃~40℃ 15%RH~80%RH | |
Transport & storage temperure & humidity | -20℃~55℃ <93%RH | |
Operation atmospheric pressure | 80Kpa~106Kpa | |
Transport & storage atmospheric pressure | 50Kpa~106Kpa | |
Dimension | 471.5mm(L)*402.0mm(W)*309.0mm(H) | |
Electric shock protection | Class I, type B | |
Device weight | 8kg | |
Arm circumference | 17-42cm | |
Blood oxygen | Probe | Dual-wavelength LED |
Wave length | Red light: 663nm, Infrared: 890nm | |
Range | 35%~100% | |
Power of maximum light output | ≤2mW | |
Blood oxygen rate accuracy | Range: 70%~100%, ±2% | |
Pulse rate accuracy | Range: 30~250bpm, ±2% | |
Operation temperature | 5℃~40℃ | |
Operation humidity | 15%~95% | |
Atmospheric pressure | 70kpa~106kpa | |
Power input | From main device by RS232 | |
ECG | Leads | 6 or 12 leads |
Collection | Syhchronization | |
Calibration voltage | 1mV±5% | |
Polarization resistance voltage | ±300mV | |
Sensitivity | 5, 10, 20(mm/mV) | |
Input impedance | ≥5MΩ | |
Input loop current | <0.05uA | |
Heart rate range | 20-300bmp/min | |
Noise level | ≤15uVp-p | |
Filtering | EMG Filtering | |
Baseline filtering | ||
AC filtering | ||
Common mode rejection ratio | >90dB | |
Time constant | ≥3.2s | |
Frequency response | 0.05Hz~150Hz(-3.0dB/+0.4dB) | |
Rhythmic lead | Any leads optional | |
Base line adjustment | Automatic | |
Patient leak current | <10uA(220V-240V) | |
Patient auxiliary current | ≤0.1uA(DC) | |
Safety standard | IEC II/CF | |
Sampling frequency | 500Hz | |
Electrode | Chest electrodes and limb electrodes adopt international colors, each matches different color | |
Blood glucose Uric acid Total cholesterol | Measurement range | Blood glucie: 1.1-33.3mmol/L(20-600mg/dL) Uric acid: 0.18-1.19mmol/L(3-20mg/dL) cholesterol: 2.59-10.35mmol/L(100-400mg/dL) |
Measurement time | blood glucoe: 5s±0.5s Uric acid: 15S±0.5S Total cholesterol: 26S±0.5S | |
Reference for normal | Blood glucose before meal: 3.9mmol/L-6.1 mmol/L Blood glucose after 2 hours of meal: <7.8 mmol/L | |
Uric acid of male: 0.21~0.43mmol/L | ||
Uric acid of female: 0.16~0.36mmol/ | ||
Uric acid of children: 0.12~0.33mmol/L | ||
Total cholesterol: 2.86~5.98mmol/L | ||
Accuracy | ±0.3(test by standard resistance slip) | |
Display | mmol/Lx and time display | |
Inbuilt battery | 3V Lithium battery | |
Blood glucose | Sample type | Capillary vessel whole blood sample |
Mesurement range | 10-600 mg/dL(0.6-33.3mmol/L) | |
Sample volumn | 0.3 microlitre | |
Test period | 3 seconds | |
Calibration | Plasma or similar product | |
HCT range | 20-60% | |
RFID | Standard: IS0/IEC 15693 | |
Read/write distance: 2cm | ||
Antenna: integrated | ||
Frequence: 13.56MHz | ||
Measurement theory for blood glucose | Electrochemistry, Optical spectrum | |
Storage capacity | 200 | |
Operation temperature | Lipid profile: 18-30℃(64-86℉) Blood glucose: 10-40℃ (50-104℉) | |
Operation humidity | 10-90% | |
Storage temperature | 2-30℃(36-80℉) | |
Display | LCD | |
Dimension | 61*109*23(mm) | |
Weight | 77.5(with battery)±1g | |
Battery life time | >1000 cycle use |