Module Number |
SK-E500(SONKA Medical) |
||
Dimensions |
Package dimensions: 480*360*220mm |
||
Gross weight:8.2kg Net weight:4.8kg |
|||
Category |
Descriptions |
Parameters |
|
Identification login |
Login methods |
Any type of reader can be integrated,this is customized modification |
|
Psychological evaluation |
Customized function |
Symptom checking list 90 questionnaire list with evaluation report |
|
Vision, teeth, WHR |
Manual input results, could be customized |
||
Height & Weight Scale |
Module number |
Need to connect with L08 Height weight scale |
|
Probe type |
Ultrasonic probe |
||
Height range |
70.0~210cm |
||
Weight range |
5~200kg |
||
Weight accuracy |
±0.1kg |
||
Height accuracy |
±0.5cm |
||
Blood pressure unit |
Range |
Pressure: 0-299mmHg/0-39.9Kpa |
|
Pulse: 40 -180 times/min |
|||
accuracy |
Pressure: < ±3mmHg(±0.5Kpd),Pulse: ±5% |
||
Working temperature & humidity |
+10℃~+40℃, 30%RH~85%RH |
||
Transportation/Storage temperature & humidity |
-20℃~+55℃, <93%RH |
||
Operating atmospheric pressure |
80kpa~106kpa |
||
Cuff circumstance |
15cm~42cm |
||
Power supply |
From control board |
||
Blood oxygen probe |
Sensor |
Dual-wavelength LED |
|
Wave length |
Glow: 663nm Infrared: 890nm |
||
Range |
35%-100% |
||
Max. Light output power |
<2mW |
||
Accuracy |
Difference at ±2% within 70%-100% |
||
Pulse rate error |
30-250bpm, error is ±2bpm or ±2%, take bigger value |
||
Working temperature |
5℃-40℃ |
||
Relative humidity |
15%-95%(non condensation) |
||
Atmosphere pressure |
70kpa-106kpa |
||
Power supply |
From control board |
||
Forehead infrared radiation thermometer |
Test method |
Infrared wireless hand-held temperature gun |
|
Accuracy |
0.1 ℃ |
||
Operation & storage temperature |
10~40℃, 0~50℃ |
||
Operation & storage humidity |
≤85% |
||
Power supply |
From control board |
||
Dimension |
150*75*40mm |
||
Weight |
180g |
||
Human temperature range |
32.0~42.5℃ |
||
Accuracy |
≤±0.3℃ |
||
Power consumption |
≤120mw |
||
Detection distance |
5 to 8 cm |
||
Auto-off |
after 8 seconds |
||
Blood glucose, uric acid, total cholesterol analyzer |
Specimen |
Finger tip capillary whole blood |
|
Specimen voulumn |
Blood glucose: 0.9uL, Total cholesterol: 10uL, Uric acid: 1uL |
||
Measurement period |
10s (Blood glucose), 26s(Cholesterol), 15s(Uric acid) |
||
Range |
Blood glucose: 1.1-33.3mmol/L(20-600mg/dL) |
||
Uric acid: 0.18-1.19mmol/L(3-20mg/dL) |
|||
Cholesterol: 2.59-10.35mmol/L(100-400mg/dL) |
|||
Accuracy: Blood glucose |
"When result is less than 4.2mmol/L the difference is within ±0.83mmol/L when result is more than 4.2mmol/L the difference is ±20%" |
||
Accuracy: Uric acid |
(0.18mmol/L—1.19mmol/L), coefficient of variation value is within ±10%, measurement result's difference between reference result is within ±20% |
||
Accuracy: Total Cholesterol |
(2.59mmol/L—10.35mmol/L),coefficient of variation value is within±15%, measurement result's difference between reference result is within±20% |
||
Hemoglobin tester |
Specimen |
Finger tip capillary whole blood |
|
Volume |
1uL |
||
Test time |
8 seconds |
||
Range |
7g/dL(4.3mmol/L)--26g/dL(16.1mmol/L) |
||
21-78% Hct(calculation value) |
|||
Storage transportation temperature |
10℃-30℃(50℉-86℉) |
||
Test temperature |
10℃-40℃(50℉-104℉) |
||
Storage transportation humidity |
10%-90% |
||
Memory |
180 groups |
||
Tester dimension |
L 77*W 61*H 19mm |
||
Altitude limit |
<10000 feet(3048m) |
||
Urine tester |
Communication |
Blue tooth |
|
Theory |
Light reflection colorimetric method |
||
Speed |
60 samples/hour, highest 300 samples/hour |
||
Screen |
LCD |
||
Buttons |
5 key capacitive touching screen |
||
Weight |
160g |
||
Power |
DC 5V,1A |
||
Power adaptor |
AC100-240V,50/60HZ |
||
Dimensions |
L 110mm*W 68mm*T 27mm |
||
Power consumption |
2W |
||
Life time |
5 years |
||
"Test categories 11 (categories)" |
"LEU--Leukocyte BLD--Occult blood NIT--Nitrite KET--Ketone body UBG--Urobilinogen BIL--Bilirubin PRO--Protein GLU--Glucose pH--pH value VC--Vitamine C SG--Specific gravity " |
||
ECG |
Power input protection |
Prevent tremor |
|
Leads |
12 leads or 6 leads |
||
Analogue/Digit convert |
12 bit (precision) |
||
Range |
±5mVpp |
||
Time constant |
≥3.2s |
||
Frequency response |
0.05Hz~150Hz(-3dB) |
||
Calibration voltage |
1mV±3% |
||
Sensitivity |
2.5, 5, 10, 20(mm/mV) |
||
Input impedance |
≥50MΩ |
||
Input loop current |
<0.05uA |
||
Noise level |
<15uVp-p |
||
Baseline adjustment |
Automatic |
||
Patient leakage current |
<10uA(220V-240V) |
||
Patient auxiliary current |
<0.1uA(DC) |
||
Filtering |
EMG(Electromyography) filtering |
||
25Hz/35Hz/45Hz/off |
|||
Baseline filtering |
|||
0.05/0.15/0.25/0.5Hz |
|||
AC filter |
|||
50Hz/60Hz |
|||
Common mode rejection ratio |
100dB |
||
Rhythmic lead |
Random choose |
||
Safety standard |
IEC II/CF |
||
Ultrasonic probe for Abdomen |
Operating system and application |
Android smart phone (SAMSUNG S8, HUAWEI MATE 10) / Windows tablet, computer, laptop |
|
Advantages |
low power consumption, which can connected to android smart phone |
||
Scanning mode |
electric convex |
||
Display mode |
B, B/B, B/M, 4B |
||
Gray scale |
256 |
||
Scanning depth |
maximum 240mm |
||
TGC |
8TGC adjustments |
||
Cine loop |
512 frames |
||
Gain |
0-100dB adjustable |
||
Language |
English/Chinese |
||
Central frequency |
3.5MHz(2.5-4.5MHz) |
||
Probe port |
USB |
||
Colors |
9 |
||
Image conversion |
left/right, up/down |
||
Application |
OB/GYN, Urology, Abdomen, Emergency, and ICU |
||
Net weight |
0.2KG |
||
Ultrasound scan for superficial tissues |
Operating system and application |
Android smart phone (SAMSUNG S8, HUAWEI MATE 10) / Windows tablet, computer, laptop |
|
Advantages |
low power consumption, which can connected to android smart phone |
||
Scanning mode |
electric linear |
||
Display mode |
B, B/B, B/M, 4B |
||
Gray scale |
256 |
||
Scanning depth |
30-120mm |
||
TGC |
8TGC adjustments |
||
Cine loop |
512 frames |
||
Gain |
0-100dB adjustable |
||
Language |
English/Chinese |
||
Central frequency |
7.5MHz(5-10MHz) |
||
Probe port |
USB |
||
Colors |
9 |
||
Image conversion |
left/right, up/down |
||
Application |
Shallow application, ultrasound-guided percutaneous drainage Small parts, such as thyroid, joint, blood vessel and so on |
||
Net weight |
0.2KG |
||
Touch screen |
Size |
10.1 inches |
|
Origin of coordinate |
Right downside |
||
Rohs standard |
Compliance |
||
Resolution |
1280(RGB)*800(WXGA) |
||
HW ratio |
16:10 (width: height) |
||
Pixel layout |
RGB vertical layout |
||
Dot pitch |
0.0565*0.1695mm (horizontal*vertical) |
||
Pixel spacing |
0.1695*0.1695mm (horizontal*vertical) |
||
Display area |
216.96*135.60mm (horizontal*vertical) |
||
Visible area |
216.66*138.60mm (horizontal*vertical) |
||
Dimension |
227.42*147.69mm (horizontal*vertical) |
||
Mother board |
CPU |
RK3288 4 cores Cortex-A17, 1.8G Hz |
|
GPU |
Mail-T764, Support TE,ASTC,AFBC |
||
SDRAM |
DDR3 2G(could change to 4G) |
||
FLASH |
EMMC FLASH 8GB/16G/32G, Support SATA disc, TF card Max. at 32G |
||
OS |
Android 5.1 |
||
Display interface |
"1 x HDMI 2.0 , Support 4K@60 frames output 1 x MIPI, 1 x EDP, 2 x LVDS LCD interfaces" |
||
Camera interface |
"1 x DVP camera(Max. 5Mpixel) 1 x MIPI-CSI camera (Max.13Mpixel )" |
||
Touch screen |
"I2C interface(Multi point resistance touch,Multi point capacitance touch). Support USBMulti point infrared touch,Multi point nano film touch, Multi point acoustic touch,Multi point optical touch" |
||
Communication |
RJ45, 100M/1000M ethernet port |
||
WIFI, support 2.4G/5G WIFI, support WI-FI802.11 a/b/g/n protocol |
|||
Bluetooth V2.1+EDR/Bluetooth 3.0/3.0+HS/4.0 |
|||
Bluetooth V2.1+EDR/Bluetooth 3.0/3.0+HS/4.0 |
|||
Interfaces |
4 channel serial ports,support serial port with flow control |
||
4 channel I2C interfaces |
|||
2 x USB2.0 HOST,1 x USB2.0 OTG |
|||
1 channel SPI interface |
|||
1 channel I2S interface |
|||
1 channel ADC interface |
|||
1 channel SDIO output |
|||
3 keypads self programmed |
|||
Real-time clock |
Inbuilt real-time clock, support timing ON-OFF tablet |
||
Watchdog |
Support software, hardware watchdog |
||
Audio |
Support MP3,WMA,WAV, APE,FLAC,AAC, OGG,M4A,3GPP |
||
Video |
Support H264,VP8,MAV,WMV,AVS,263,MPEG4 with 1080P |
||
Printer |
"Printer 1: 58mm width ticket print, for text result(come with standard package) Printer 2: A4 printer, for ECG and Ultrosound image result(Seperate package)" |
||
Power supply |
Noise |
Typical 35dB |
|
Voltage range |
100~240Vac |
||
Frequency |
47~63Hz, typical 50Hz |
||
Output voltage |
12.6Vdc |
||
Output power |
25.2W |