Introducing the Sonka Telemedicine Hospital Telehealth Kiosk Disease Diagnosis Machine, a revolutionary disease detective machine designed to provide accurate and fast disease diagnosis through telemedicine technology. This advanced telemedicine telehealth kiosk disease diagnosis equipment is built to streamline the diagnostic process in hospitals, clinics, and healthcare facilities. By combining cutting-edge body scanning, telemedicine capabilities, and diagnostic tools, this device allows healthcare professionals to remotely monitor, assess, and diagnose a wide range of diseases and health conditions. With its user-friendly interface and seamless integration into healthcare systems, the Sonka disease diagnosis kiosk ensures timely intervention and enhanced patient care.
Module Number
|
SK-E500(SONKA Medical)
|
||
Category
|
Descriptions
|
Parameters
|
|
WHR
|
Manual input datas
|
||
Weight Scale
|
Module number
|
Need to connect with L08 Height weight scale
|
|
Probe type
|
Ultrasonic probe
|
||
Height range
|
70.0ï½210cm
|
||
Weight range
|
5ï½200kg
|
||
Weight accuracy
|
±0.1kg
|
||
Height accuracy
|
±0.5cm
|
||
Blood pressure unit
|
Range
|
Pressure: 0-299mmHg/0-39.9Kpa
|
|
Pulse: 40 -180 times/min
|
|||
accuracy
|
Pressure: < ±3mmHg(±0.5Kpd),Pulse: ±5%
|
||
Working temperature & humidity
|
+10â~+40â, 30%RH~85%RH
|
||
Transportation/Storage temperature & humidity
|
-20â~+55â, <93%RH
|
||
Operating atmospheric pressure
|
80kpa~106kpa
|
||
Cuff circumstance
|
15cmï½42cm
|
||
Power supply
|
From control board
|
||
Blood oxygen probe
|
Sensor
|
Dual-wavelength LED
|
|
Wave length
|
Glow: 663nm Infrared: 890nm
|
||
Range
|
35%-100%
|
||
Max. Light output power
|
<2mW
|
||
Accuracy
|
Difference at ±2% within 70%-100%
|
||
Pulse rate error
|
30-250bpm, error is ±2bpm or ±2%, take bigger value
|
||
Working temperature
|
5â-40â
|
||
Relative humidity
|
15%-95%(non condensation)
|
||
Atmosphere pressure
|
70kpa-106kpa
|
||
Power supply
|
From control board
|
||
Body Temperature Test with Non-contactless
|
Test method
|
Infrared wireless hand-held temperature gun
|
|
Accuracy
|
0.1 â
|
||
Operation & storage temperature
|
10ï½40â, 0ï½50â
|
||
Operation & storage humidity
|
â¤85%
|
||
Power supply
|
From control board
|
||
Dimension
|
112*82*124cm
|
||
Weight
|
180g
|
||
Human temperature range
|
32.0ï½42.5â
|
||
Accuracy
|
â¤Â±0.3â
|
||
Power consumption
|
â¤120mw
|
||
Detection distance
|
5 to 8 cm
|
||
Auto-off
|
after 8 seconds
|
||
Blood glucose, uric acid, total cholesterol analyzer
|
Specimen
|
Finger tip capillary whole blood
|
|
Specimen voulumn
|
Blood glucose: 0.9uL, Total cholesterol: 10uL, Uric acid: 1uL
|
||
Measurement period
|
10s (Blood glucose), 26s(Cholesterol), 15s(Uric acid)
|
||
Range
|
Blood glucose: 1.1-33.3mmol/L(20-600mg/dL)
|
||
Uric acid: 0.18-1.19mmol/L(3-20mg/dL)
|
|||
Cholesterol: 2.59-10.35mmol/L(100-400mg/dL)
|
|||
Accuracy: Blood glucose
|
"When result is less than 4.2mmol/L the difference is within ±0.83mmol/L when result is more than 4.2mmol/L the difference is
±20%" |
||
Accuracy: Uric acid
|
ï¼0.18mmol/Lâ1.19mmol/Lï¼, coefficient of variation value is within ±10%, measurement result's difference between reference result
is within ±20% |
||
Accuracy: Total Cholesterol
|
ï¼2.59mmol/Lâ10.35mmol/Lï¼,coefficient of variation value is within±15%, measurement result's difference between reference result is
within±20% |
||
ECG
|
Power input protection
|
Prevent tremor
|
|
Leads
|
12 leads or 6 leads
|
||
Analogue/Digit convert
|
12 bit (precision)
|
||
Range
|
±5mVpp
|
||
Time constant
|
â¥3.2s
|
||
Frequency response
|
0.05Hz~150Hz(-3dB)
|
||
Calibration voltage
|
1mV±3%
|
||
Sensitivity
|
2.5, 5, 10, 20(mm/mV)
|
||
Input impedance
|
â¥50MΩ
|
||
Input loop current
|
ï¼0.05uA
|
||
Noise level
|
ï¼15uVp-p
|
||
Baseline adjustment
|
Automatic
|
||
Patient leakage current
|
ï¼10uA(220V-240V)
|
||
Patient auxiliary current
|
ï¼0.1uA(DC)
|
||
Filtering
|
EMG(Electromyography) filtering
|
||
25Hz/35Hz/45Hz/off
|
|||
Baseline filtering
|
|||
0.05/0.15/0.25/0.5Hz
|
|||
AC filter
|
|||
50Hz/60Hz
|
|||
Common mode rejection ratio
|
100dB
|
||
Rhythmic lead
|
Random choose
|
||
Safety standard
|
IEC II/CF
|
||
Touch screen
|
Size
|
10.1 inches
|
|
Origin of coordinate
|
Right downside
|
||
Rohs standard
|
Compliance
|
||
Resolution
|
1280ï¼RGBï¼*800ï¼WXGAï¼
|
||
HW ratio
|
16:10 (width: height)
|
||
Pixel layout
|
RGB vertical layout
|
||
Dot pitch
|
0.0565*0.1695mm (horizontal*vertical)
|
||
Pixel spacing
|
0.1695*0.1695mm (horizontal*vertical)
|
||
Display area
|
216.96*135.60mm (horizontal*vertical)
|
||
Visible area
|
216.66*138.60mm (horizontal*vertical)
|
||
Dimension
|
227.42*147.69mm (horizontal*vertical)
|
||
Printer
|
"Printer 1: 58mm width ticket print, for text result(come with standard package) Printer 2: A4 printer, for ECG and Ultrosound
image result(Seperate package)" |
||
Power supply
|
Noise
|
Typical 35dB
|
|
Voltage range
|
100ï½240Vac
|
||
Frequency
|
47ï½63Hz, typical 50Hz
|
||
Output voltage
|
12.6Vdc
|
||
Output power
|
25.2W
|