The Sonka Portable Blood Testing & ECG Monitoring Device is a high-precision clinical analytical instrument designed for comprehensive health diagnostics. This advanced system integrates urine, cholesterol, diabetes, and glucose analysis with a portable ECG machine featuring 12-lead monitoring, making it an essential tool for clinical lab use and mobile medical services. Engineered for fast and accurate blood testing, this device enhances diagnostic efficiency while ensuring reliability in diverse healthcare settings. Its compact and user-friendly design allows seamless operation in both clinical and point-of-care environments.
Type
|
SK-GS6
|
||
Project name
|
Parameter
|
Specification
|
|
Body Temperature
|
Display precise digits
|
0.1 ℃
|
|
Human body temperature measurement mode
|
32.0~42.5℃
|
||
Object temperature measurement mode
|
0~100℃
|
||
Accuracy
|
≤±0.3℃
|
||
Measuring distance
|
5 to 8 cm
|
||
Automatic shut-down
|
About 15 seconds
|
||
Blood Pressure
|
Measuring range
|
Pressure (0~270)mmHg [(0~36)kpa]
|
|
Pulse rate 40 times/per minute~180 times/minute
|
|||
Measurement accuracy
|
Pressure within ±3mmHg (±0.4kpa)
|
||
Pulse rate within ±5%
|
|||
Applicable circumference range of cuff
|
15cm~42cm
|
||
12-lead ECG
|
Collection method
|
12-lead synchronous ECG Wilson
|
|
Sampling frequency
|
500Hz
|
||
Gain setting and accuracy
|
Should provide 5 mm/mV (x0.5), 10 mm/mV (x1), 20 mm/mV (x2)
|
||
Blood Oxygen
|
Measuring range
|
35%~ 100%;
|
|
Maximum average optical output power
|
≤2mW
|
||
Measurement error
|
In the range of 70%~100%, the measurement error is ±2%
|
||
Pulse rate measurement error
|
30~250bpm The monitoring error is ±2bpm or ±%2, whichever is the largest
|
||
Blood Sugar, Uric Acid, Total Cholesterol
|
Specimen
|
Fingertip microvascular whole blood
|
|
Detection time
|
Blood sugar: within 10 seconds Uric acid: within 15 seconds Total cholesterol: within 26 seconds
|
||
examination range
|
Blood sugar: 20-600mg/dL (1.1-33.3mmol/L)
Uric acid: 3-20mg/dL (0.18-1.19mmol/L) Total cholesterol: 100-400mg/dL (2.59-10.35mmol/L) |
||
Urinalysis
|
Detection principle
|
RGB three primary color detection principle
|
|
interface
|
Micro USB interface, Bluetooth wireless communication (Bluetooth version machine)
|
||
Relative humidity
|
≤80%
|
||
Dimensions
|
126mm(L)*74mm(W)*30mm(H)
|
||
Hemoglobin
|
measure time
|
≤10 seconds
|
|
Equipment detection range
|
7.0-26.0g/dL (4.3-161.1mmol/L); 20-75% blood cell volume (converted)
|
||
Power Adapter
|
Standard operating voltage range
|
100~240Vac, typical 220Vac
|
|
Motherboard
|
CPU
|
Super quad-core Cortex-A17, frequency up to 1.8GHz
|
|
GPU
|
ARM Mali-T764 GPU, support TE, ASTC, AFBC memory compression technology
|
Copyright © 2025 by Shenzhen Sonka Medical Technology Co., Limited - Privacy policy