The SONKA Customized Commercial Telemedicine Health Checkup House Solution is a versatile and powerful smart full body check device designed to meet the diverse needs of hospitals, clinics, and public health initiatives. This telemedicine station integrates a blood pressure monitor, blood oxygen fast test, and body composition analysis system into one compact unit, offering comprehensive health metrics in real-time. As automatic medical equipment, it ensures accurate diagnostics and seamless operation, making it ideal for healthcare providers and businesses. Whether for routine checkups, chronic disease management, or preventive health programs, the SONKA Health Checkup House Solution is your trusted partner in modern healthcare delivery.
Blood Pressure Monitor: Accurately measures blood pressure for health assessment.
Blood Oxygen Fast Test: Provides quick and reliable blood oxygen saturation readings.
Health Measurement Medical Kiosk: Combines multiple health monitoring tools in one device.
Powerful Smart Full Body Check: Delivers comprehensive health metrics, including body composition, vital signs, and more.
Body Composition Analysis System: Tracks body fat percentage, muscle mass, water retention, and other key indicators.
Telemedicine Station: Enables remote monitoring and data sharing with healthcare providers.
Automatic Medical Equipment: Features seamless operation for user-friendly health checkups.
Customizable Design: Tailored to meet specific healthcare or commercial needs.
Hospitals and Clinics: Use as automatic medical equipment for patient diagnostics, remote monitoring, and routine checkups.
Public Health Campaigns: Deploy in community centers or health fairs for accessible health screenings.
Chronic Disease Management: Monitor patients with chronic conditions remotely using telemedicine station capabilities.
Corporate Wellness Programs: Support employee health initiatives by offering on-site health checkups.
Fitness Centers: Help members track body composition, vital signs, and blood oxygen levels as part of their fitness journey.
Rural Healthcare: Extend healthcare access to remote or underserved areas with powerful smart full body check solutions.
Revolutionize healthcare delivery with the SONKA Customized Commercial Telemedicine Health Checkup House Solution – the ultimate health measurement medical kiosk and body composition analysis system for accurate and comprehensive health monitoring. Whether for hospitals, clinics, or public health initiatives, this telemedicine station is your trusted partner in modernizing healthcare solutions.
Project name
|
Parameter
|
Specification
|
Machine parameters
|
Data output interface
|
LAN network port*1 USB*2
|
Power supply
|
100V~240V,50/60Hz
|
|
Power rating
|
(100W)Maximum
|
|
LCD screen
|
21.5inch
|
|
ID card reader
|
||
Operating humidity range (storage temperature range)
|
5℃~45℃(-10℃~+60℃)
|
|
Operating System
|
Windows 10 (More than 32)
|
|
Data Transmission Mode
|
internet access、WIFI
|
|
Overall Dimension
|
1800(length)*1200( Width)*2450(height )mm
|
|
Weight
|
About 220KG
|
|
Height
|
Measuring system
|
Ultrasonic measurement (high precision temperature difference compensation)
|
Measuring range
|
70.0~205cm
|
|
Permissible error
|
±0.5cm
|
|
Weight
|
Measuring system
|
Precision balance beam pressure sensor weighing
|
BMI
|
The automatic intelligence calculates the body mass index
|
|
Measuring range
|
1~300kg
|
|
Permissible error
|
±0.1kg
|
|
Body fat
|
Measuring frequency
|
Multi frequency 4- electrode
|
Electrode material
|
Electroplating material
|
|
Measuring range
|
200~1000Ω
|
|
Body temperature (DT-8836)
|
Display exact number
|
0.1 ℃
|
Human body temperature measurement
|
32.0~42.5℃
|
|
Object temperature measurement
|
0~100℃
|
|
Accuracy
|
≤±0.3℃
|
|
Power Consumption
|
≤120mw
|
|
Measuring distance
|
5-8cm
|
|
Auto Power -Off
|
About 15 second
|
|
Blood pressure(RBP-7000)
|
Display
|
Digital display
|
Measuring method
|
Oscillographic method
|
|
Measuring range
|
Pressure (0~300) mmHg [ (0~ 40)kPa]
rate 30/minute~200/minute |
|
Accuracy
|
Pressure 士2mmHg(士0.267kPa)within
Rate士2% within |
|
Screen
|
LCD screen
|
|
Data Transmission Mode
|
232 port/USB
|
|
Power Supply
|
Power Adapter(Input AC100V~240V,50/60Hz,Output DC12V,3.5A)
|
|
Operating temperature and humidity
|
5℃~40℃,15%RH~80%RH
|
|
Transport and storage temperature and humidity
|
-20℃~+55℃,≤93%RH
|
|
Operating atmospheric pressure
|
80kPa~106kPa
|
|
Transport and storage atmospheric pressure
|
50kPa~106kPa
|
|
Overall dimensions
|
387.7mm(L)×244.1mm(W)×340.2mm(H)
|
|
Net Weight
|
About 6.0Kg
|
|
Cuff applies to perimeter range
|
17cm~42cm
|
|
Blood oxygen KS-CM01
|
Sensor
|
Dual wavelength light emitting diode
|
Wavelength
|
Red Lights:663nm
|
|
Infrared light:890nm
|
||
Measuring range
|
35%~100%;
|
|
Maximum average optical Output power
|
≤2mW
|
|
Permissible error
|
The measurement error was ±2% in the range of 70% to 100%
|
|
Pulse rate measurement error
|
Tolerance of 30-250bpm was ±2bpm or ±%2, which was the maximum
|
|
Single lead ECG
|
Operating temperature
|
5℃~40℃
|
Environment temperature
|
30%~80% Non - Condensing
|
|
Range of atmospheric Pressure
|
70KPa~106KPa
|
|
Heart rate measurement range
|
30bpm~240bpm
|
|
Accuracy of heart rate Measurement
|
The maximum value is ± 2BPM or ±2
|
|
Waveform display sensitivity
|
5.0mm/mv error±10%
|
|
Scanning speed
|
20mm/s error±10%
|
|
Input impedance
|
≥5.0Ω
|
|
Operating voltage
|
d.c.2.5V±0.2V
|
|
Blood sugar, uric acid, total cholesterol
(BeneCheck BKM13-1) |
Specimens
|
Whole fingertip micro-vascular blood
|
Detection time
|
Blood sugar 10 seconds; uric acid 15 seconds; total cholesterol 26 seconds
|
|
Measuring range
|
blood glucose:20-600mg/dL (1.1-33.3mmol/L)
Uric Acid:3-20mg/dL(0.18-1.19mmol/L) Total cholesterol:100-400mg/dL(2.59-10.35mmol/L) |
|
Liquid volume inspector
|
blood glucose 0.9uL,Total cholestero l10uL, Uric Acid 1uL
|
|
Storage Temperature
|
10℃-30℃
|
|
Operating Temperature
|
10℃-40℃
|
|
Relative humidity
|
<95%
|
|
Memory capacity
|
Blood glucose 360 group, total cholesterol 50 group, uric acid 50 group
|
|
Battery type
|
A 3V (CR2032) button lithium battery
|
|
Validity of battery
|
About 1000 tests
|
|
Camera
|
Pixels
|
5 million
|
Port
|
USB 2.0
|
|
Driver
|
free drive
|
|
Thermal printer(SP-EU58)
|
Printing method
|
Line thermal printing
|
Printing paper
|
(straight roll) Heat sensitive 57.5mm× paper roll 100mm (MAX)
|
|
Carriage Paper Width
|
57.5±0.5 mm
|
|
Effective print width
|
48mm
|
|
Image resolution
|
8 /mm(203dp)
|
|
Printing speed
|
Max 80mm/S(No more than 25% print points per line)
|
|
Paper thickness
|
0.06~0.08 mm
|
|
Print head span
|
50KM
|
|
Operating ambient temperature/humidity
|
0-50℃/10-80%
|
|
Temperature/humidity of the storage environment
|
-20-60℃/10-90%
|
Telemedicine Kiosk:
|
SK-T9
|
|
Height
|
Height sensor
|
Ultrasound probe(Buy from USA)
|
Range
|
70.0~200cm
|
|
Accuracy
|
0.01cm
|
|
Weight
|
BMI
|
Automatic calculation
|
Loadcell
|
500kg
|
|
Accuracy
|
±0.1kg
|
|
Body composition analysis
|
Frequencies
|
5kHz/50kHz/250kHz/500kHz
|
Measurement
|
Body fat, visceral fat, body water, muscle, bone mass, basal metabolism
|
|
Measurement current
|
90μA or below
|
|
Electrode material
|
Electroplating material
|
|
Measurement range
|
75.0~1,500.00Ω(0.1Ω unit)
|
|
Measurement location
|
Trunk, 4 limbs
|
|
Body temperature
|
Test method
|
Infrared wireless hand-held temperature gun
|
Accurate to
|
0.1 ℃
|
|
Operation & storage temperature
|
10~40℃, 0~50℃
|
|
Operation & storage humidity
|
≤85%
|
|
Power
|
DC 9V
|
|
Dimension
|
150*75*40mm
|
|
Weight
|
180g
|
|
Human temperature range
|
32.0~42.5℃
|
|
Object temperature range
|
0~100℃
|
|
Accuracy
|
≤±0.3℃
|
|
Power consumption
|
≤120mw
|
|
Detection distance
|
5 to 8 cm
|
|
Auto-off
|
after 15 seconds
|
|
Blood pressure monitor
|
Blood pressure range
|
(0~270)mmHg,[(0~36)Kpa]
Pulse rate: 40-180bpm |
Storage capacity
|
100 pcs of record
|
|
Accuracy
|
Blood pressure: <±2mmHg(±0.267kpa)
|
|
Pulse: <±2%
|
||
Power
|
AC 100-240V,50-60Hz,1.6-0.8A
|
|
Operation temperature & humidity
|
5℃~40℃ 15%RH~80%RH
|
|
Transport & storage temperure & humidity
|
-20℃~55℃ <93%RH
|
|
Operation atmospheric pressure
|
80Kpa~106Kpa
|
|
Transport & storage atmospheric pressure
|
50Kpa~106Kpa
|
|
Dimension
|
471.5mm(L)*402.0mm(W)*309.0mm(H)
|
|
Electric shock protection
|
Class I, type B
|
|
Device weight
|
8kg
|
|
Arm circumference
|
17-42cm
|
|
Blood oxygen
|
Probe
|
Dual-wavelength LED
|
Wave length
|
Red light: 663nm, Infrared: 890nm
|
|
Range
|
35%~100%
|
|
Power of maximum light output
|
≤2mW
|
|
Blood oxygen rate accuracy
|
Range: 70%~100%, ±2%
|
|
Pulse rate accuracy
|
Range: 30~250bpm, ±2%
|
|
Operation temperature
|
5℃~40℃
|
|
Operation humidity
|
15%~95%
|
|
Atmospheric pressure
|
70kpa~106kpa
|
|
Power input
|
From main device by RS232
|
|
ECG
|
Leads
|
6 or 12 leads
|
Collection
|
Syhchronization
|
|
Calibration voltage
|
1mV±5%
|
|
Polarization resistance voltage
|
±300mV
|
|
Sensitivity
|
5, 10, 20(mm/mV)
|
|
Input impedance
|
≥5MΩ
|
|
Input loop current
|
<0.05uA
|
|
Heart rate range
|
20-300bmp/min
|
|
Noise level
|
≤15uVp-p
|
|
Filtering
|
EMG Filtering
|
|
Baseline filtering
|
||
AC filtering
|
||
Common mode rejection ratio
|
>90dB
|
|
Time constant
|
≥3.2s
|
|
Frequency response
|
0.05Hz~150Hz(-3.0dB/+0.4dB)
|
|
Rhythmic lead
|
Any leads optional
|
|
Base line adjustment
|
Automatic
|
|
Patient leak current
|
<10uA(220V-240V)
|
|
Patient auxiliary current
|
≤0.1uA(DC)
|
|
Safety standard
|
IEC II/CF
|
|
Sampling frequency
|
500Hz
|
|
Electrode
|
Chest electrodes and limb electrodes adopt international colors, each matches different color
|
|
Blood glucose
Uric acid Total cholesterol |
Measurement range
|
Blood glucie: 1.1-33.3mmol/L(20-600mg/dL)
Uric acid: 0.18-1.19mmol/L(3-20mg/dL) cholesterol: 2.59-10.35mmol/L(100-400mg/dL) |
Measurement time
|
blood glucoe: 5s±0.5s
Uric acid: 15S±0.5S Total cholesterol: 26S±0.5S |
|
Reference for normal
|
Blood glucose before meal: 3.9mmol/L-6.1 mmol/L
Blood glucose after 2 hours of meal: <7.8 mmol/L |
|
Uric acid of male: 0.21~0.43mmol/L
|
||
Uric acid of female: 0.16~0.36mmol/
|
||
Uric acid of children: 0.12~0.33mmol/L
|
||
Total cholesterol: 2.86~5.98mmol/L
|
||
Accuracy
|
±0.3(test by standard resistance slip)
|
|
Display
|
mmol/Lx and time display
|
|
Inbuilt battery
|
3V Lithium battery
|
|
Blood glucose
|
Sample type
|
Capillary vessel whole blood sample
|
Mesurement range
|
10-600 mg/dL(0.6-33.3mmol/L)
|
|
Sample volumn
|
0.3 microlitre
|
|
Test period
|
3 seconds
|
|
Calibration
|
Plasma or similar product
|
|
HCT range
|
20-60%
|
|
RFID
|
Standard: IS0/IEC 15693
|
|
Read/write distance: 2cm
|
||
Antenna: integrated
|
||
Frequence: 13.56MHz
|
||
Measurement theory for blood glucose
|
Electrochemistry, Optical spectrum
|
|
Storage capacity
|
200
|
|
Operation temperature
|
Lipid profile: 18-30℃(64-86℉)
Blood glucose: 10-40℃ (50-104℉) |
|
Operation humidity
|
10-90%
|
|
Storage temperature
|
2-30℃(36-80℉)
|
|
Display
|
LCD
|
|
Dimension
|
61*109*23(mm)
|
|
Weight
|
77.5(with battery)±1g
|
|
Battery life time
|
>1000 cycle use
|
Copyright © 2025 by Shenzhen Sonka Medical Technology Co., Limited - Privacy policy