The SONKA Medical Health Kiosk is an advanced intelligent health examination device designed to provide comprehensive and convenient health assessments. This body check-up kiosk integrates cutting-edge technology with cloud-based healthcare solutions, making it perfect for clinics, healthcare centers, and public spaces. Offering basic body health metrics such as weight, height, BMI, blood pressure, and more, this health kiosk ensures accurate diagnostics and real-time health monitoring. Whether for routine checkups, preventive health programs, or remote patient care, the SONKA Health Kiosk is your trusted partner in modern clinic health solutions.
Intelligent Health Examination: Provides comprehensive health metrics, including weight, height, BMI, and blood pressure.
Body Check-Up Kiosk: Combines multiple health monitoring tools in one compact and user-friendly unit.
Cloud-Based Healthcare: Enables real-time data sharing and remote monitoring with healthcare providers.
Health Kiosk: Features a clear digital display and intuitive controls for easy operation.
Durable Construction: Built with high-quality materials for long-lasting performance in clinical settings.
Multi-Parameter Analysis: Tracks vital signs, BMI, and other health indicators for comprehensive assessments.
Clinic Health Solutions: Tailored to meet the needs of clinics, healthcare centers, and public health initiatives.
Portable and Compact: Sleek design fits seamlessly into any environment.
Clinics and Healthcare Centers: Use as clinic health solutions for patient diagnostics, remote monitoring, and routine checkups.
Public Health Campaigns: Deploy in community centers or health fairs for accessible health screenings.
Preventive Health Programs: Monitor health metrics to detect potential issues early and promote wellness.
Corporate Wellness Programs: Support employee health initiatives by offering on-site health checkups.
Rural Healthcare: Extend healthcare access to remote or underserved areas with cloud-based healthcare solutions.
Fitness Centers: Help members track weight, height, BMI, and vital signs as part of their fitness journey.
Transform healthcare delivery with the SONKA Medical Health Kiosk Intelligent Health Examination Basic Body Health Check-Up Kiosk – the ultimate health kiosk and body check-up kiosk for accurate and comprehensive health monitoring. Whether for clinics, healthcare centers, or public health initiatives, this cloud-based healthcare solution is your trusted partner in modernizing healthcare services.
Telemedicine Kiosk:
|
SK-T9
|
|
Height
|
Height sensor
|
Ultrasound probe(Buy from USA)
|
Range
|
70.0~200cm
|
|
Accuracy
|
0.01cm
|
|
Weight
|
BMI
|
Automatic calculation
|
Loadcell
|
500kg
|
|
Accuracy
|
±0.1kg
|
|
Body composition analysis
|
Frequencies
|
5kHz/50kHz/250kHz/500kHz
|
Measurement
|
Body fat, visceral fat, body water, muscle, bone mass, basal metabolism
|
|
Measurement current
|
90μA or below
|
|
Electrode material
|
Electroplating material
|
|
Measurement range
|
75.0~1,500.00Ω(0.1Ω unit)
|
|
Measurement location
|
Trunk, 4 limbs
|
|
Body temperature
|
Test method
|
Infrared wireless hand-held temperature gun
|
Accurate to
|
0.1 ℃
|
|
Operation & storage temperature
|
10~40℃, 0~50℃
|
|
Operation & storage humidity
|
≤85%
|
|
Power
|
DC 9V
|
|
Dimension
|
150*75*40mm
|
|
Weight
|
180g
|
|
Human temperature range
|
32.0~42.5℃
|
|
Object temperature range
|
0~100℃
|
|
Accuracy
|
≤±0.3℃
|
|
Power consumption
|
≤120mw
|
|
Detection distance
|
5 to 8 cm
|
|
Auto-off
|
after 15 seconds
|
|
Blood pressure monitor
|
Blood pressure range
|
(0~270)mmHg,[(0~36)Kpa]
Pulse rate: 40-180bpm |
Storage capacity
|
100 pcs of record
|
|
Accuracy
|
Blood pressure: <±2mmHg(±0.267kpa)
|
|
Pulse: <±2%
|
||
Power
|
AC 100-240V,50-60Hz,1.6-0.8A
|
|
Operation temperature & humidity
|
5℃~40℃ 15%RH~80%RH
|
|
Transport & storage temperure & humidity
|
-20℃~55℃ <93%RH
|
|
Operation atmospheric pressure
|
80Kpa~106Kpa
|
|
Transport & storage atmospheric pressure
|
50Kpa~106Kpa
|
|
Dimension
|
471.5mm(L)*402.0mm(W)*309.0mm(H)
|
|
Electric shock protection
|
Class I, type B
|
|
Device weight
|
8kg
|
|
Arm circumference
|
17-42cm
|
|
Blood oxygen
|
Probe
|
Dual-wavelength LED
|
Wave length
|
Red light: 663nm, Infrared: 890nm
|
|
Range
|
35%~100%
|
|
Power of maximum light output
|
≤2mW
|
|
Blood oxygen rate accuracy
|
Range: 70%~100%, ±2%
|
|
Pulse rate accuracy
|
Range: 30~250bpm, ±2%
|
|
Operation temperature
|
5℃~40℃
|
|
Operation humidity
|
15%~95%
|
|
Atmospheric pressure
|
70kpa~106kpa
|
|
Power input
|
From main device by RS232
|
|
ECG
|
Leads
|
6 or 12 leads
|
Collection
|
Syhchronization
|
|
Calibration voltage
|
1mV±5%
|
|
Polarization resistance voltage
|
±300mV
|
|
Sensitivity
|
5, 10, 20(mm/mV)
|
|
Input impedance
|
≥5MΩ
|
|
Input loop current
|
<0.05uA
|
|
Heart rate range
|
20-300bmp/min
|
|
Noise level
|
≤15uVp-p
|
|
Filtering
|
EMG Filtering
|
|
Baseline filtering
|
||
AC filtering
|
||
Common mode rejection ratio
|
>90dB
|
|
Time constant
|
≥3.2s
|
|
Frequency response
|
0.05Hz~150Hz(-3.0dB/+0.4dB)
|
|
Rhythmic lead
|
Any leads optional
|
|
Base line adjustment
|
Automatic
|
|
Patient leak current
|
<10uA(220V-240V)
|
|
Patient auxiliary current
|
≤0.1uA(DC)
|
|
Safety standard
|
IEC II/CF
|
|
Sampling frequency
|
500Hz
|
|
Electrode
|
Chest electrodes and limb electrodes adopt international colors, each matches different color
|
|
Blood glucose
Uric acid Total cholesterol |
Measurement range
|
Blood glucose: 1.1-33.3mmol/L(20-600mg/dL)
Uric acid: 0.18-1.19mmol/L(3-20mg/dL) cholesterol: 2.59-10.35mmol/L(100-400mg/dL) |
Measurement time
|
blood glucose: 5s±0.5s
Uric acid: 15S±0.5S Total cholesterol: 26S±0.5S |
|
Reference for normal
|
Blood glucose before meal: 3.9mmol/L-6.1 mmol/L
Blood glucose after 2 hours of meal: <7.8 mmol/L |
|
Uric acid of male: 0.21~0.43mmol/L
|
||
Uric acid of female: 0.16~0.36mmol/
|
||
Uric acid of children: 0.12~0.33mmol/L
|
||
Total cholesterol: 2.86~5.98mmol/L
|
||
Accuracy
|
±0.3(test by standard resistance slip)
|
|
Display
|
mmol/Lx and time display
|
|
Inbuilt battery
|
3V Lithium battery
|
|
Blood glucose
|
Sample type
|
Capillary vessel whole blood sample
|
Mesurement range
|
10-600 mg/dL(0.6-33.3mmol/L)
|
|
Sample volume
|
0.3 microlitre
|
|
Test period
|
3 seconds
|
|
Calibration
|
Plasma or similar product
|
|
HCT range
|
20-60%
|
|
RFID
|
Standard: IS0/IEC 15693
|
|
Read/write distance: 2cm
|
||
Antenna: integrated
|
||
Frequence: 13.56MHz
|
||
Measurement theory for blood glucose
|
Electrochemistry, Optical spectrum
|
|
Storage capacity
|
200
|
|
Operation temperature
|
Lipid profile: 18-30℃(64-86℉)
Blood glucose: 10-40℃ (50-104℉) |
|
Operation humidity
|
10-90%
|
|
Storage temperature
|
2-30℃(36-80℉)
|
|
Display
|
LCD
|
|
Dimension
|
61*109*23(mm)
|
|
Weight
|
77.5(with battery)±1g
|
|
Battery life time
|
>1000 cycle use
|
Copyright © 2025 by Shenzhen Sonka Medical Technology Co., Limited - Privacy policy