Introducing the Sonka Body Health Checkup Kiosk, the ultimate solution for comprehensive health monitoring. This cutting-edge device combines multiple diagnostic technologies, including body scanning, telemedicine health analysis, urine testing, SpO2 monitoring, and hematology analysis—all in one streamlined system. Designed for clinics, hospitals, and wellness centers, the Sonka Body Health Checkup Kiosk enables instant, accurate health assessments without the need for manual intervention. By integrating telemedicine capabilities, it allows healthcare professionals to remotely monitor and diagnose patients with ease, making healthcare more accessible and efficient. Ensure better patient care and health outcomes with this all-in-one diagnostic tool.
By incorporating the latest in medical technology, the Sonka Body Health Checkup Kiosk empowers individuals and healthcare providers to take a proactive approach to health management.
Touchscreens
|
size
|
15.6
|
(body) temperature
|
Displaying the exact number of digits
|
0.1 °C
|
Body temperature measurement mode
|
32.0 to 42.5°C
|
|
Object temperature measurement mode
|
0 to 100°C
|
|
precision
|
≤±0.3°C
|
|
power wastage
|
≤120mw
|
|
measuring distance
|
5 to 8 cm
|
|
automatic shutdown
|
About 15 seconds.
|
|
12-lead ECG
|
Collection method
|
12-lead synchronized ECG Wilson
|
Power input
|
d.c5.0V (powered by computer USB port)
|
|
Sampling frequency
|
500Hz
|
|
Calibration voltage
|
Calibration voltage:1 mV+5%.
|
|
Gain Settings and Accuracy
|
5 mm/mV (x0.5), 10 mm/mV (x1), 20 mm/mV (x2 ) shall be provided
|
|
Input impedance
|
≥5.0Ω
|
|
Low Frequency Characteristics
|
Time constant not less than 3.2 s
|
|
oximetry
|
sensors
|
Dual Wavelength Light Emitting Diodes
|
wave length
|
Red light:663nm
|
|
Infrared light:890nm
|
||
Measurement Range
|
35% to 100%;
|
|
Maximum output power
|
≤2mW
|
|
measurement error
|
The measurement error is ±2% in the range of 70% to 100%.
|
|
Pulse rate measurement error
|
30 to 250bpm The monitoring error is ±2bpm or ±%2, whichever is greatest.
|
|
sphygmometer
|
Display method
|
Large LCD Digital
|
Measurement method
|
signal wave method
|
|
Measurement Range
|
Blood pressure:30~280mmHg
|
|
Pulse rate:40 to 195 beats/min
|
||
precision
|
Pressure ±3mmHg
|
|
Pulse rate number ±5%
|
||
Pressurization / Pressure Relief
|
Pressurization/decompression using a microelectronic air pump control system
|
|
Storage function
|
100 sets of measured values with date/time (no loss of memory)
|
|
Suitable for arm circumference
|
22cm to 32cm
|
|
power supply
|
DC 6V
|
|
Use of temperature and humidity
|
+5°C - +40°C RH ≤ 80% (measurement outside the range, measurement results have deviations)
|
|
Preservation of temperature and humidity
|
-20℃-+55℃ RH≤93% (measurement outside the range, measurement results have deviations)
|
|
Operating atmospheric pressure
|
525-795 mmHg
|
|
Transport and storage atmospheric pressure
|
375-795 mmHg
|
|
A4 Printer
Hewlett-Packard ( HP108A ) |
resolution (of a photo)
|
B&W (best mode): up to 1,200x1,200dpi; B&W (normal mode): up to 600x600dpi
|
Printer Language
|
GDI (host-based language)
|
|
Print speed
|
B&W (normal mode, A4): up to 20 pages/min; B&W (long-edge feed, A5): up to 30 pages/min
|
|
Print load
|
Up to 10,000 pages
|
|
First Print Time
|
B&W (A4, ready mode): only 8.3 seconds; B&W (A4, sleep mode): as fast as 18 seconds
|
|
weight
|
4.18 kg
|
|
interface
|
High-speed USB 2.0 port
|
|
System Parameters
|
Windows:7(32/64 bit), 2008 Server R2,8(32/64 bit),8.1(32/64 bit),10(32/64 bit),2012 Server,2016 Server
|
|
size
|
331*215*178 mm
|
|
RAM
|
64 MB
|
|
power supply
|
Power supply type: built-in power supply; power requirements: 110 volts input voltage: 110 to 127 volts AC, 50/60 Hz; 220 volts
input voltage: 220 to 240 volts AC, 50/60 Hz |
|
Blood sugar, uric acid, total cholesterol
|
autopsy
|
Fingertip microvascular whole blood
|
Detection time
|
Blood sugar:in 10 seconds Uric acid:in 15 seconds Total cholesterol:in 26 seconds
|
|
Scope of testing
|
Blood glucose:20-600mg/dL (1.1-33.3mmol/L)
Uric acid:3-20mg/dL (0.18-1.19mmol/L) Total cholesterol:100-400mg/dL (2.59-10.35mmol/L) |
|
volume of the body to be examined
|
Blood glucose 0.9uL, total cholesterol 10uL, uric acid 1uL
|
|
Storage temperature
|
10°C - 30°C
|
|
Operating temperature
|
10°C - 40°C
|
|
relative humidity
|
<95%
|
|
Memory capacity
|
Blood glucose 360 group, total cholesterol 50 group, uric acid 50 group
|
|
Battery life
|
Approx. 1000 measurements
|
|
Data output interface
|
LAN interface
|
|
Supply voltage
|
220 AC (50Hz/60Hz)
|
|
rating
|
(100W) Max.
|
|
Operating humidity range (storage temperature range)
|
5°C to 45°C (-10°C to +60°C)
|
|
operating system
|
Windows 7, 32-bit or above
|